检测到连接到适配器的磁盘架配置不一致
适用场景
- ONTAP 9
- FAS2750
问题描述
EMS消息会报告以下 错误:
no-01:
no-02:
7/13/2023 12:57:19 Node-01 ALERT ses.inconsistent.config: Inconsistent configuration detected for shelf connected to adapter 0b.
7/13/2023 12:56:53 Node-02 ALERT ses.inconsistent.config: Inconsistent configuration detected for shelf connected to adapter 0b.
SAS-EXPANDER-MAP
显示了以下内容:no-01:
Expanders on channel 0a:
Level 1: WWN 500a098008481111, ID 10, Serial Number ' SHFFG1938000223', Product 'DS22412IOM12A ', Rev '0300', Slot A
Level 2: WWN 500a098008578a3d, ID 20, Serial Number ' SHFNC2052000228', Product 'DS22412IOM12A ', Rev '0300', Slot A
Expanders on channel 0b:
Level 1: WWN 500a09800ee76abx, ID 0, Serial Number ' SHJSG2322000080', Product 'DS22412IOM12E ', Rev '0240', Slot A
Level 2: WWN 500a0980085793ax, ID 20, Serial Number ' SHFNC2052000220', Product 'DS22412IOM12A ', Rev '0300', Slot B
Level 3: WWN 500a098008480fex, ID 10, Serial Number ' SHFFG1938000220', Product 'DS22412IOM12A ', Rev '0300', Slot B
Level 4: WWN 500a09800ee722bx, ID 0, Serial Number ' SHJSG2322000080', Product 'DS22412IOM12E ', Rev '0240', Slot B
no-02:
Expanders on channel 0a:
Level 1: WWN 500a098008578a3x, ID 20, Serial Number ' SHFNC2052000220', Product 'DS22412IOM12A ', Rev '0300', Slot A
Level 2: WWN 500a09800848111x, ID 10, Serial Number ' SHFFG1938000220', Product 'DS22412IOM12A ', Rev '0300', Slot A
Expanders on channel 0b:
Level 1: WWN 500a09800ee722bx, ID 0, Serial Number ' SHJSG2322000080', Product 'DS22412IOM12E ', Rev '0240', Slot B
Level 2: WWN 500a098008480fex, ID 10, Serial Number ' SHFFG1938000220', Product 'DS22412IOM12A ', Rev '0300', Slot B
Level 3: WWN 500a0980085793ax, ID 20, Serial Number ' SHFNC2052000220', Product 'DS22412IOM12A ', Rev '0300', Slot B
Level 4: WWN 500a09800ee76abx, ID 0, Serial Number ' SHJSG2322000080', Product 'DS22412IOM12E ', Rev '0240', Slot A