SwitchPowerFail_Alert - 集群交换机 AutoSupport 消息
适用于
- ONTAP 9
- 集群网络交换机
- NetApp 集群交换机
- 运行状况监控器进程 cshm 的 Call home:SwitchPowerFail_Alert
事件摘要
当集群交换机运行状态读取为失败、缺失或未运行时,会发送 SwitchPowerFail_Alert
验证
AutoSupport 消息
HA Group Notification (Health Monitor process cshm: SwitchPowerFail_Alert[Swtich Name/PowerSupply-1]) ALERT
EMS 日志
- event log show -severity * -message-name callhome*
[Node Name: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm SwitchPowerFail_Alert[Switch Name/PowerSupply-1].
- event log show -severity * -message-name hm.alert.raised*
[netapp-01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchPowerFail_Alert , Alerting Resource = switch name/PowerSupply raised by monitor cluster-switch
命令行
- system health alert show -node <node name> -monitor cluster-switch -alert-id SwitchPowerFail_Alert
Node: Reporting Node Name
Monitor: cluster-switch
Class of Alert: SwitchPowerFail_Alert
Severity of Alert: Major
Probable Cause: Power_supply_failure
Probable Cause Description: "$(cluster_switch_power.psu-name)" on switch "$(cluster_switch_power.device)" is missing or is not operational.
Possible Effect: Power supply redundancy on switch "$(cluster_switch_power.device)" might be lost.
Corrective Actions: 1) Ensure that the power supply units supplying power to the switch are turned on.
2) Ensure that the power cord is securely connected to the power supply of the switch.