SwitchPowerFail_Alert -集群交换机AutoSupport消息
适用场景
- ONTAP 9
- 集群网络交换机
- NetApp集群交换机
- 为运行状况监控进程cshm呼叫主目录:SwitchPowerFail_Alert
事件摘要
当集群交换机运行状态显示为失败、缺失或未运行时、将发送SwitchPowerFail_Alert
验证
AutoSupport 消息
HA Group Notification (Health Monitor process cshm: SwitchPowerFail_Alert[Swtich Name/PowerSupply-1]) ALERT
EMS日志
- event log show -serity *-message-name callHome*
[Node Name: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm SwitchPowerFail_Alert[Switch Name/PowerSupply-1].
- event log show -serity *-message-name hm.alge.rayed*
[netapp-01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchPowerFail_Alert , Alerting Resource = switch name/PowerSupply raised by monitor cluster-switch
命令行
- system运行状况警报 show -node <node name> -monitor cluster-switch -alter-id SwitchPowerFail_Alert
Node: Reporting Node Name
Monitor: cluster-switch
Class of Alert: SwitchPowerFail_Alert
Severity of Alert: Major
Probable Cause: Power_supply_failure
Probable Cause Description: "$(cluster_switch_power.psu-name)" on switch "$(cluster_switch_power.device)" is missing or is not operational.
Possible Effect: Power supply redundancy on switch "$(cluster_switch_power.device)" might be lost.
Corrective Actions: 1) Ensure that the power supply units supplying power to the switch are turned on.
2) Ensure that the power cord is securely connected to the power supply of the switch.
解决方法
- 验证维护是否在AutoSupport自动通报时间戳期间进行或已计划维护。
- 验证数据中心内是否有电源问题描述。
- 验证电源是否正在接收 配电单元(PDU)的电源
- 验证电源是否安装正确且未松动。
- 如果可能、请重新拔插受影响的电源。
如果确认电源 有缺陷、请更换电源:
- 对于Broadcom交换机、请联系 Broadcom 以获得帮助
- 对于Cisco交换机、请联系 Cisco 以获得帮助
- 对于NVIDIA交换机、请联系 NVIDIA 以获得帮助
- 对于CN1610交换机、请联系 NetApp技术支持 以获得帮助