适用场景

  • SAN
  • MetroCluster交换机
  • Brocade交换机 G720、G620、G630、6520、6510、6505、5100、X6-4和X6-8
  • Brocade主干DCX8510

问题描述

Brocade 6520、6510、6505或5100交换机上报告电源或风扇出现故障:

Brocade DCX8510主干网报告电源出现故障

  • 报告故障PS:

psshow :

Power Supply #1 is OK
Airflow Direction : Port side Exhaust (Reverse)
Power Supply #2 is faulty*
* = No system control access to power supply.

  • 报告故障风扇:

fanshow        :
Fan 1 is Ok, speed is 4071 RPM
Fan 2 is faulty
Fan 3 is Ok, speed is 4119 RPM
Fan 4 is Ok, speed is 18977 RPM
Fan 5 is Unknown

  • Brocade X6-4和Brocade X6-8上报告电源或风扇出现故障:

psshow        :

Power Supply #1 is OK
V10N18,   DUCXXXXXXHJ      ,23-0000161-01,A0,DELTA,ECXXXXXXX42     ,00,DUXXXX8N
Power Supply #2 is faulty
V10N22,   DUCXXXXXX1H      ,23-0000161-01,A0,DELTA,ECXXXXXXX42     ,00,DUXXXX2N

fanshow        :
Fan 1 is Ok, speed is 4067 RPM
Fan 2 is faulty
Fan 3 is Ok, speed is 4067 RPM

  • Brocade X6-4导向器:两个风扇组件,非端口侧排气或进气,用于1+1冗余。每个组件包含2个风扇、总共4个风扇。系统需要4个正常工作的风扇中的3个风扇才能运行。一个风扇部件可以热插拔、但必须立即更换。
  • Brocade X6-8导向器:三个风扇组件,非端口侧排气或进气,用于2+1冗余。每个组件包含2个风扇、共6个。系统需要6个正常运行的风扇中的5个风扇才能运行。一个风扇部件可以热插拔、但必须立即更换。
  • Brocade 6505:交换机还提供了一个用于单个热插拔PS设备的选项。如果此电源发生故障、将关闭开关、并且看不到任何LED指示灯。
  • Brocade DCX8510主干网
    • 电源故障

xxxxx20 Power Supply #1 is faulty Brocade DCX8510-8  WWN Serial Num: AFXxxxxL00K     Power Supply #1 is faulty
POWER SUPPLY  Unit: 1
Header Version:         2
Power Consume Factor:   0
Factory Part Num:       23-0000067-02
Factory Serial Num:     AGCxxxxLB8Z

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.