如何确定电源的 NetApp 部件号 Brocade 交换机的电源( PS/PSU )或风扇
适用场景
- SAN
- MetroCluster
- Brocade 交换机 G620 , 6520 , 6510 , 6505 , 5100 , X6-4 和 X6-8
问题描述
Brocade 6520 、 6510 、 6505 或 5100 交换机上报告的电源或风扇出现故障:
- 报告错误的 PS :
psshow :
Power Supply #1 is OK
Airflow Direction : Portside Exhaust (Reverse)
Power Supply #2 is faulty*
* = No system control access to power supply.
- 报告风扇故障:
fanshow :
Fan 1 is Ok, speed is 4071 RPM
Fan 2 is faulty
Fan 3 is Ok, speed is 4119 RPM
Fan 4 is Ok, speed is 18977 RPM
Fan 5 is Unknown
- Brocade X6-4 和 Brocade X6-8 上报告的电源或风扇出现故障:
psshow :
Power Supply #1 is OK
V10N18, DUCXXXXXXHJ ,23-0000161-01,A0,DELTA,ECXXXXXXX42 ,00,DUXXXX8N
Power Supply #2 is faulty
V10N22, DUCXXXXXX1H ,23-0000161-01,A0,DELTA,ECXXXXXXX42 ,00,DUXXXX2N
fanshow :
Fan 1 is Ok, speed is 4067 RPM
Fan 2 is faulty
Fan 3 is Ok, speed is 4067 RPM
Brocade X6-4 导向器:两个风扇组件(非端口端排气或进气)用于 1+1 冗余。每个组件包含 2 个风扇、总共 4 个。系统需要 4 个正常工作的风扇中的 3 个。一个风扇组件可以热插拔、但必须立即更换。
Brocade X6-8 Director :三个风扇组件、非端口端排气或进气、可实现 2+1 冗余。每个组件总共包含 2 个风扇,共 6 个。系统需要 6 个正常工作的风扇中的 5 个。一个风扇组件可以热插拔、但必须立即更换。
6505 交换机还提供了一个单热交换 PS 单元选项。如果此电源出现故障,则交换机将关闭,并且不会出现任何 LED 指示灯。