问题

  • 事件日志中会报告以下电池 警报。示例:
[Node-01: env_mgr: nvmem.battery.capLow:alert]: The NVMEM battery capacity is low (1 cycles).
[Node-01: env_mgr: nvmem.battery.fccLowCrit:EMERGENCY]: The NVMEM battery full-charge capacity is critically low (15 ). To prevent data loss, the system will shut down in 20 minutes.
[Node-01: env_mgr: callhome.battery.warning:alert]: Call home for BATTERY (remain capacity critical low) WARNING.
[Node-01: env_mgr: callhome.battery.failure:EMERGENCY]: Call home for BATTERY (full capacity critical low) CRITICAL.
[Node-01: statd: monitor.nvramLowBattery:EMERGENCY]: NVRAM battery is dangerously low.
[Node-01: statd: monitor.nvramLowBattery.notice:notice]: If the NVRAM battery is dangerously low, the system shuts down automatically every 24 hours to encourage you to replace it. If you reboot the system it will run for another 24 hours before shutting down.
[Node-01: statd: callhome.battery.low:alert]: Call home for BATTERY_LOW.
[Node-01: statd: monitor.shutdown.nvramLowBattery.pending:alert]: NVRAM battery is dangerously low. Halting system in 24 hours. Replace the battery immediately!
  • 如果未采取任何操作,则节点将每 24 小时重新启动一次,并显示以下事件。 示例:

[Node-01: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (BATTERY (full capacity critical low) for 20 mins)

[Node-01: env_mgr: nvmem.battery.capNormal:notice]: The NVMEM battery capacity is normal.
[Node-01: statd: monitor.nvramLowBattery:EMERGENCY]: NVRAM battery is dangerously low.
[Node-01: statd: monitor.nvramLowBattery.notice:notice]: If the NVRAM battery is dangerously low, the system shuts down automatically every 24 hours to encourage you to replace it. If you reboot the system it will run for another 24 hours before shutting down.
[Node-01: statd: callhome.battery.low:alert]: Call home for BATTERY_LOW.

  • 在 ONTAP 启动期间,可能会报告以下错误。 示例:

WARNING:  The battery is experiencing a critical failure:
           - Battery full charge capacity is too low
           Without a working battery, the system cannot retain data
           during a power outage, which can result in data loss.
           Power down the system and verify that the battery is
           properly installed.
           To ignore this failure and boot the system in a mode
           where data loss might occur, press 'c' followed by 'Enter'

  •  SP-LATEST-IPMI 部分中的传感器报告以下内容。  AutoSupport 示例:

======================================
hsamcmd --fault-show-all
===============================
tag  origin  fld                                     fault reason                                    count  time                       
---- ------- ----                                    -------------                                   ------ -----                      
1    bmc     /chassis-1/controller-a/nvbatt-1        Bat_Rem_Cap: Current Sensor 94 LNC              1      Sat Jul 19 23:25:29 2025
2    bmc     /chassis-1/controller-a/nvbatt-1        Bat_Rem_Cap: Current Sensor 94 LCR              1      Sat Jul 19 23:25:29 2025
3    bmc     /chassis-1/controller-a/nvbatt-1        Bat_Full_Cap: Current Sensor 95 LNC             1      Sat Jul 19 23:25:29 2025
4    bmc     /chassis-1/controller-a/nvbatt-1        Bat_Full_Cap: Current Sensor 95 LCR             1      Sat Jul 19 23:25:29 2025
5    bmc     /chassis-1/controller-a/nvbatt-1        Bat_Dstg_Cycles: Battery Sensor 99 Fault       2      Sat Jul 19 23:25:29 2025

Fault Lights On:
             /chassis-1                                                                              6     
             /chassis-1/controller-a                                                                 6     
             /chassis-1/controller-a/nvbatt-1                                                        6     

Sensor Name              State          Current    Critical     Warning     Warning    Critical
                                        Reading       Low         Low         High       High
-------------------------------------------------------------------------------------------------

Bat Design Cap           normal         10500 W*hr     --          --          --          --       
Bat Dstg Cycles         critlow           1 cycles    2 cycles    3 cycles   --          --       
Bat Cycle Count          normal             3 cycles   --          --          --         450 cycles
Bat FRU LED                                OFF
Battery Charge Failed?                   FALSE
Battery Charge Bad?                      TRUE
Battery Capacity Message                  BAD
Battery RemCap Desc                      READY
             
NV0 Battery State                       FULLY_DISCHARGED
NV0 Battery Voltage      normal          8150 mV     5500 mV     5750 mV     8300 mV     8500 mV    

Battery Charge                             BAD
Dblade Battery Status                  FULLY_DISCHARGED
Dblade Temp                             NORMAL_TEMP

  • 即使在受影响的节点重新通电后,也会出现相同的错误。

追加信息

主动修复
BMC 固件升级后电池固件无法更新到版本 B1

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.