跳转到主内容

节点重新启动时NVDIMM出现错误

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • AFF A800、AFF C800、ASA A800、ASA C800
  • AFF A400、AFF C400、ASA A400、ASA C400
  • FAS8300、FAS8700
  • ONTAP 9

问题描述

  • 节点关闭 、控制台日志中出现以下错误:

CPU initialization.
Running full memory initialization.
DIMM F0: NVDIMM in ERROR condition (status = 00000801).

[nvdimm.nvmem.destage.failure:ALERT]:NVMEM subsystem fail to start or complete destage process, please check battery or NVDIMM..

  • BMC事件日志可能会报告不可更正的ECC错误:

c17 | 05/02/2024 | 05:55:46 | Watchdog 2 #0xb1 | Timer interrupt (NMI/SMS/OS) | Asserted
c18 | 05/02/2024 | 05:55:46 | Critical Interrupt #0xb0 | NMI/Diag Interrupt | Asserted
c19 | 05/02/2024 | 05:55:49 | Watchdog 2 #0xb1 | Hard reset (SMS/OS) | Asserted
c1a | 05/02/2024 | 05:55:49 | Power Unit #0xb2 | Power reset | Asserted | from channel 15
c23 | 05/02/2024 | 05:58:49 | Memory #0x08 | Uncorrectable ECC | Asserted  

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.