SwitchPowerNotOperational_Alert—AutoSupport 消息
适用场景
- ONTAP 9
- MetroCluster 运行状况监控(光纤通道交换机)
- 集群网络交换
- Brocade
- Cisco
- 对于运行状况监控器进程cshm、请致电主页:SwitchPowerNotOperational_Alert
事件摘要
当集群交换机的运行状态显示为"不运行"时、系统将发送SwitchPowerNotOperational_Alert。
验证
AutoSupport 消息
HA Group Notification from Cluster-04 (Health Monitor process cshm: SwitchPowerNotOperational_Alert[CN1610-down/PowerSupply-2]) ALERT
EMS日志
event log show -severity * -message-name callhome*
[Node Name: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchPowerNotOperational_Alert[Switch Name/PowerSupply-1].
命令行
system health alert show -node <node name> -monitor cluster-switch -alert-id SwitchPowerNotOperational_Alert
Node Reporting Node Name
Monitor cluster-switch
Alert ID SwitchPowerNotOperational_Alert
Alerting Resource CN1610-up/PowerSupply-1
Subsystem Switch-Health
Indication Time <date/time>
Perceived Severity Major
Probable Cause Out_of_service
Corrective Actions 1) Ensure that the power supply unit (PSU) is turned on through switch CLI.
2) Run diagnostics on switch to check the operational status of PSU. For instructions about how to run switch diagnostics, see the switch's configuration guide
解决方法
请执行以下步骤:
- 验证是否已安装电源。
- 验证电源是否已通电。
- 如果确定电源存在故障、请予以更换。
- 对于Brocade交换机、请联系NetApp技术支持以获得帮助。
- 对于Cisco交换机、请联系Cisco以获得帮助
- 对于CN1610交换机、请联系NetApp技术支持以获得帮助。
追加信息