跳转到主内容

FabricSwitchPowerFail_Alert—MetroCluster交换机AutoSupport消息

Views:
27
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

状态信息

适用场景

  • ONTAP 9
  • MetroCluster光纤通道交换机

事件摘要

如果光纤通道交换机运行状态报告为"Failed"、则会发送FabricSwitchPowerFail_Alert。

验证

AutoSupport 消息

HA Group Notification (Health Monitor process schm: FabricSwitchPowerFail_Alert[]) ALERT

EMS日志

::> event log show -severity * -message-name callhome*

[netapp-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: FabricSwitchPowerFail_Alert[//].

::> event log show -severity * -message-name hm.alert.raised*

[netapp-01: schmd: hm.alert.raised:alert]: Alert Id = FabricSwitchPowerFail_Alert , Alerting Resource = // raised by monitor system-connect

命令行

::> system health alert show -node <node name> -monitor system-connect -alert-id FabricSwitchPowerFail_Alert

                      Node: Reporting Node Name
                   Monitor: system-connect
            Class of Alert: FabricSwitchPowerFail_Alert
         Severity of Alert: Major
            Probable Cause: Power_supply_failure
Probable Cause Description: A power supply unit on the switch "Switch Name" is not operational.
           Possible Effect: Power supply redundancy on switch "Switch Name" is lost.   
        Corrective Actions: 1) Check the error details by using the command "storage switch show -error -switch-name                                Switch_Name".
                      2) Identify the faulty power supply unit by using the command "storage switch show -power -                               switch-name Switch_Name".
                      3) Ensure that the power supply unit "Power Supply #1" is properly inserted into the chassis of                                the switch "Switch_Name" and fully operational.

解决方法

  1. 验证维护是否在AutoSupport自动通报时间戳期间进行或已计划维护。
  2. 验证数据中心内是否有电源问题描述。
  3. 验证电源是否正在接收 配电单元(PDU)的电源
  4. 验证电源是否安装正确且未松动。
    1. 拔下并重新连接电源线、以重新拔插电源线
  5. 如果可能、请重新拔插受影响的电源。

如果确认电源 有缺陷、请更换电源:

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.