跳转到主内容

已在FCVI端口xx上重置

Views:
14
Visibility:
Public
Votes:
1
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • ONTAP 9
  • MetroCluster FC
  • 光纤通道虚拟接口(FC-VI)
  • Brocade交换机

问题描述

  • 节点事件日志指示经常重置FVI端口、并且收到端口上的帧错误

FC-VI adapter: Received bad frame on port xx. Mailbox-1 = 24, Mailbox-2 = 1857. Resetting the port.

  • NetApp报告 ""Reset occured on FCVI port <>、并且连接的Brocade 交换机端口存在过多错误。
  • Porterrshow 输出报告 大量错误,包括 链路故障、pcs错误、C3 TX丢弃和丢失信号错误
    猪展    :
          frames    enc   crc   crc   too   too   bad   enc   disc   link   loss   loss   frjt   fbsy  c3timeout   pcs   uncor
        tx    rx    in   err   g_eof  shrt   long   eof    out   c3   fail   sync   sig          tx   rx    err   err
    1:   1.0g   2.4g   0    0    0    0    0    0    0    2.5k  22.4k   0    8.9k   0    0   557    1    25.3k   0
  • Switchshow 将端口状态报告为online""。

Index Port Address  Media Speed   State     Proto
==================================================
1   1   070100   id   16G   Online   FC  F-Port  50:0a:09:82:07:f4:xy:xx

 

  • Not Available即使端口状态为联机、sfpshow输出中的RX和TX功率也会显示为""。

=============
Port  1:
=============
RX Power   :   Not Available
TX Power   :   Not Available

 

  • errdump 日志下的端口转接事件报告:

2023/12/28-18:05:40, [AN-1014], 14352, FID 128, INFO, switch, Frame timeout detected, tx port 1 rx port 1, sid ffffxx, did 701xx, timestamp 2023-12-28 18:05:40 .

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.