存储上的 SFP 功率低于建议值
适用于
- FAS/AFF 系统
- ONTAP 9
- 光纤通道 (FC)
问题描述
- FC 链路断开、链路摆动和/或 FCP 性能下降。
Sysconfig -a显示状态为"link not connected"或"link disconnected"slot 0: Fibre Channel Target Host Adapter 0h
(QLogic 8324 (8362) rev. 2, <LINK NOT CONNECTED>)
Firmware rev: 8.9.0
Flash rev: 4.1.0
Host Port Addr: 000000
Connection: No link
Switch Port: Unknown xxxx:41
SFP Vendor Name: AVAGO
SFP Vendor P/N: AFBR-57F5MZ-NA1
SFP Vendor Rev: 01
SFP Connector: LC
SFP Capabilities: 4, 8, 16 Gbit/SecFCP-ADAPTER.XMLLOG IN ASUP 将受影响端口的 Rx/Tx 值显示为 0.0 uWatts。Rx : 0.0 (uWatts)
Tx : 0.0 (uWatts)- 收到以下关于 NetApp 上存储 LIF 的错误:
Service: Interface FCP XXX.FC_LIF State: CRITICAL Time: Wed Mar 15 15:16:13 CET 2023 Description: CRIT - State: online, 8 Gbit/s (wrong speed, expected 16 Gbit/s)(!!), Address x0:0a:09:84:80:74:xy:xx, Read: 1235654.27, Write: 9303298.57, Read OPS: 71, Write OPS: 138, Latency: 1.15 ms, Read Latency: 0.03 ms, Write Latency: 1.08ms
- 已记录以下
EMS事件 -
Tue Feb 27 00:20:29 +0000 [netapp: fct_tpd_work_thread_0: scsitarget.fct.sfpTxPowerLow:alert]: The SFP in FC target adapter 0f reports that it is transmitting (TX) at a low level of power. Operating value 263 (uWatts), Threshold value 317 (uWatts).
network fcp adapter showon ONTAP CLI 显示低 TX 功耗:
Received Optical Power 570.7 (uWatts)
SPF Transmitted Optical Power 123.8 (uWatts)
- 低 Rx 功率表示存储端口上游出现问题,即交换机端的电缆和 SFP 等硬件故障。 这与存储上的 SFP 无关。
- 低 Tx 功率表示存储端口出现问题。
- 以下值为近似值:
|
SFP 版本 |
光值范围 |
|---|---|
|
短波 2/4/8gb SFP 接收功率范围 短波 2/4/8gb SFP 发射功率范围 |
-6 dBm (250 uWatt) 至 -2 dBm (630 uWatt) -6 dBm (250 uWatt) 至 0 dBm (1000 uWatt) |
|
短波 4/8/16gb SFP 接收功率范围 短波 4/8/16gb SFP 发射功率范围 |
-5.2 dBm (300 uWatt) 至 0 dBm (1000 uWatt) -5.2 dBm (300 uWatt) 至 -1 dBm (790 uWatt) |
|
短波 8/16/32gb SFP 接收功率范围 短波 8/16/32gb SFP 发射功率范围 |
-4.6 dBm (340 uWatt) 至 2 dBm (1580 uWatt) -4.6 dBm (340 uWatt) 至 2 dBm (1580 uWatt) |
- 可能在相关性中发生:
- 交换机端口上的错误计数器增加
- 主机操作系统上的 IO 故障和/或超时
- 来自主机操作系统的一个或多个故障路径
- 存储控制器上的 FC 目标端口处于状态 <
OFFLINE> 或 <LINK NOT CONNECTED> - 链路重置/端口重置
- 适配器发现挂起错误