跳转到主内容

由于交换机端SFP出现故障、在FC目标HBA上检测到链路中断事件

Views:
1
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade<a>2010005621</a>
Last Updated:

适用场景

  • ONTAP 9.
  • Brocade 交换机
  • FC

问题描述

  • 在FC目标HBA上检测到链路中断事件:
event error scsitarget.fct.linkError: FC target HBA: 0f received unexpected error: RECV_ERROR, AEN Status1: 0x8048, Status2: 0x0, Status3: 0x0
 
  • AEN 0x8048 (RECV_ERROR)EMS 日志中观察到受影响的端口:
Tue Mar 19 01:49:41  0200 [Maadi-Cluster-02: fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:0f AEN 0x8048 (RECV_ERROR) MboxStatus1 0x0 MboxStatus2 0x0
Tue Mar 19 01:58:39  0200 [Maadi-Cluster-02: fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:0f AEN 0x8048 (RECV_ERROR) MboxStatus1 0x0 MboxStatus2 0x0
Tue Mar 19 04:41:55  0200 [Maadi-Cluster-02: fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:0f AEN 0x8048 (RECV_ERROR) MboxStatus1 0x0 MboxStatus2 0x0
 
  • 端口显示为" Online 自" SYSCONFIG-A
slot 0: Fibre Channel Target Host Adapter 0f
(QLogic 8324 (8362) rev. 2, <ONLINE>)
Firmware rev:    8.9.0
Flash rev:     7.0.3
Host Port Addr:   010xxx
FC Nodename:    50:0a:09:80:xx:xx:xx:xx (500a0980xxxxxxxx)
FC Portname:    50:0a:09:82:xx:xx:xx:xx (500a0982xxxxxxxx)
Connection:     PTP, Fabric
Switch Port:    xxxxx:xx
 
Received Optical Power: 408.1 (uWatts)
SFP Transmitted Optical Power: 517.4 (uWatts)
 
Admin::> porterrshow
frames    enc   crc   crc   too   too   bad   enc  disc  link  loss  loss  frjt  fbsy  c3timeout   pcs
tx   rx    in   err   g_eof  shrt  long  eof   out  c3   fail   sync  sig          tx   rx   err
11:   3.2g  3.6g  0    0    0    0    0    0    0   1.7k  4    0    9    0    0   1.7k  3    0
 
=============
Port 11:
=============
RX Power:   -3.7   dBm (429.6uW)  0.0   uW  6550.0 uW  49.0  uW  1100.0 uW
TX Power:   -2.5   dBm (558.2 uW)  50.0  uW  800.0  uW  100.0  uW  700.0  uW

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.