跳转到主内容

SwitchPowerNotOperational_Alert—AutoSupport 消息

Views:
3
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
metrocluster
Last Updated:

适用场景

  • ONTAP 9
  • MetroCluster 运行状况监控(光纤通道交换机)
  • 集群网络交换
  • Brocade
  • Cisco
  • 对于运行状况监控器进程cshm、请致电主页:SwitchPowerNotOperational_Alert

事件摘要

当集群交换机的运行状态显示为"不运行"时、系统将发送SwitchPowerNotOperational_Alert。

验证

AutoSupport 消息

HA Group Notification from Cluster-04 (Health Monitor process cshm: SwitchPowerNotOperational_Alert[CN1610-down/PowerSupply-2]) ALERT

EMS日志

event log show -severity * -message-name callhome*

[Node Name: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchPowerNotOperational_Alert[Switch Name/PowerSupply-1].

命令行

system health alert show -node <node name> -monitor cluster-switch -alert-id SwitchPowerNotOperational_Alert

          Node   Reporting Node Name
        Monitor   cluster-switch
        Alert ID   SwitchPowerNotOperational_Alert
   Alerting Resource   CN1610-up/PowerSupply-1
       Subsystem   Switch-Health
    Indication Time   <date/time>
   Perceived Severity   Major
     Probable Cause   Out_of_service
   Corrective Actions   1) Ensure that the power supply unit (PSU) is turned on through switch CLI. 
              2) Run diagnostics on switch to check the operational status of PSU. For instructions about                 how to run switch diagnostics, see the switch's configuration guide

 

解决方法

请执行以下步骤:

  1. 验证是否已安装电源。
  2. 验证电源是否已通电。
  3. 如果确定电源存在故障、请予以更换。

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.