适用场景

  • NS224磁盘架
  • NSM固件161及更早版本

问题描述

  • NS224 磁盘架模块NSM100 错误或警报:
Wed Feb 03 18:50:32 +0100 [node_name: dsa_worker4: ses.status.battery.error:error]: NS224NSM100 (S/N SHFHU0123456789) shelf 0 on channel 0x battery failure error for Coin Battery 1: not installed or hardware failure. This element is on the rear of the shelf, in bottom module (B).
 
Wed Feb 03 18:50:42 +0100 [node_name: dsa_worker3: ses.status.battery.threshErr:alert]: NS224NSM100 (S/N SHFHU0123456789) shelf 0 on channel 0x battery failure error for Coin Battery 1: critical status. This element is on the rear of the shelf, in top module (A).
  • 存储故障输出 

::> system node run -node <node_name> -command storage show fault -v
...
Coin Cell Battery:
Element Status                      Status Bytes  Status Descriptions
    1 [NSM100 A]    : CRITICAL         02,02,0A,46   LCR
    2 [NSM100 B]    : OK                01,00,0B,34

  • 币形电池的环境错误: 
Coin Battery installed element list: 1, 2; with error: 1
Coin Battery information by element:
   [1] Voltage: 2.630
   [2] Voltage: 2.868
  • 此错误可能是间歇性的

 

 
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.