跳转到主内容

FabricSwitchFanFail或SwitchFanFail警报—AutoSupport 消息

Views:
6
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
metrocluster
Last Updated:

适用场景

  • ONTAP 9
  • 集群网络交换
  • MetroCluster光纤交换机
  • NetApp集群交换机
  • Broadcom交换机
  • Cisco 交换机
  • 对于运行状况监控进程cshm、请致电主目录: FabricSwitchFan或SwitchFanFail_Alert

事件摘要

如果未检测到风扇电源且风扇状态显示为故障、则会发送FabricFanSwitchFan或SwitchFanFail_Alert

验证

AutoSupport 消息

HA Group Notification from Node Name (Health Monitor process cshm: SwitchFanFail_Alert[Switch Name/Fan-2]) ALERT

System Notification from Node Name (Health Monitor process schm: FabricSwitchFanFail_Alert[Switch WWN]) ALERT

EMS日志

event log show -severity * -message-name callhome*

[Node Name: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: FabricFanSwitch or SwitchFanFail_Alert[Switch Name/WWN].

命令行

system health alert show -node <node name> -monitor cluster-switch -alert-id FabricSwitchFanFail_Alert

system health alert show -node <node name> -monitor cluster-switch -alert-id SwitchFanFail_Alert


Node: Netapp-a
Resource: Fan Module-3
Severity: Major
Indication Time: <date/time>
Suppress: false
Acknowledge: false
Probable Cause: The fan "Fan Module-3" on switch "Switch_Name"
has failed.
Possible Effect: Failure of the fan in the switch "Switch_Name"
might affect its cooling.
Corrective Actions: 1) Ensure that the fans in the switch are operating correctly by using the command "storage switch show -cooling".
2) Ensure that the fan FRUs are properly inserted and
operational.

解决方法

  1. 验证是否已安装电源。
  2. 验证电源是否通电。
  3. 如果确定电源有故障、请更换电源。
  • 注意:如果这是计划内维护活动的一部分、请考虑在维护期间禁用自动创建案例:

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.