由于节点端SFP出现故障、报告FVI重置
适用场景
- ONTAP 9
- MetroCluster FC
问题描述
- 在MetroCluster的两个集群上收到多条错误消息:
HA Group Notification (Reset occured on FCVI port 5c) NOTICE
Tue Mar 12 10:42:43 +0300 [Cluster1_01: ispfcvi2500_main2: fcvi.qlgc.ioErr:error]: FC-VI adapter: FCVI driver on port 5b received IO error. Status = FW detected response error(status code = 0x121), FCVI opcode = Write Request(0x1), QP name = WAFL, QP index = 2, Remote node's system id = 537123456.
- 节点端的FCVI端口脱机
- 交换机日志显示一个集群端的RX值较低:
sfpshow
On CLUSTER1 : Port 1: RX Power: -3.1 dBm (491.3uW) TX Power: -2.6 dBm (548.3 uW) On CLUSTER2 : Port 1: RX Power: -7.1 dBm (193.8uW) TX Power: -2.8 dBm (527.0 uW)
- 连接的交换机端口报告CRC错误
- FVI适配器可能会暂时显示端口已关闭
slot 5: FCVI Host Adapter 5a (QLogic 8324(2672) rev. 2, unknown) Physical link: DOWN FC Node Name: 50:0a:09:80:xx:xx:xx:xx Firmware rev: 8.01.141 Serial No: (null) Host Port Id: 0xffffffff FC Packet size: 2048 SFP Vendor: FINISAR CORP. SFP Part Number: FTLF8529Pxxxxxxx SFP Serial Number: xxxxxxx SFP Capabilities: 4, 8 or 16 Gbit SFP Wavelength: 850nm