MetroCluster 中的 FC 启动程序适配器脱机
适用场景
- ONTAP 9
- 光纤 MetroCluster
- FAS/AFA系统
问题描述
- 在光纤MetroCluster配置中、FC适配器已脱机:
cluster1::> system node run -node node1 -command sysconfig -a
slot 1: FC Host Adapter 1a (Emulex XE501 rev. 1, <OFFLINE (hard)>)
Board name: 111-03648
Serial Number: FP12345678
Firmware rev: 11.4.277.0
Host Port Id: N/A
FC Node Name: 2:000:00109b:ea9206
FC Port Name: 1:000:00109b:ea9206
Link Data Rate: N/A
- 事件日志中报告以下警报:
[Node-01: nchmd: hm.alert.raised:alert]: Alert Id = StorageFCAdapterFault_Alert , Alerting Resource = 10000010XXXX206 raised by monitor node-connect
- MetroCluster节点运行状况降级、原因是:
cluster1::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health ok
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node degraded
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster ok
13 entries were displayed.
- 节点配置可能会更改为"多路径"、而不是"四路径"配置。
- 从交换机日志中可以观察到、连接到受影响FC端口的交换机端口报告
No_Sync
或No_Light:
MCC-sw2:admin>switchshow
switchName: MCC-sw2
switchType: 181.0
switchState: Online
switchMode: Native
Index Port Address Media Speed State Proto
==================================================
8 8 070800 id 32G No_Sync FC
- 已重新拔插节点FC端口和交换机端口之间的缆线。