为什么会否决 ONTAP 聚合的交还?
适用场景
- ONTAP 9
- 高可用性管理
问题描述
在ONTAP中交还聚合的任何尝试都可能会被否决、以防止发生中断。使用以下命令确定否决来自哪个模块:
storage failover show-giveback
示例:
::> storage failover show-giveback
Partner
Node Aggregate Giveback Status
-------------- ----------------- ---------------------------------------------
Warning: Unable to list entries on node NodeA. RPC: Couldn't make connection
[from mgwd on node "NodeB" (VSID: -1) to mgwd at 169.254.127.139]
NodeB
CFO Aggregates Failed module: autosupport. Giveback vetoed:
AutoSupport collection is still in progress.
Allow up to 20 minutes for AutoSupport
processing after a takeover. Use the
"storage failover giveback -override-vetoes
true" command to override all veto checks,
including AutoSupport collection.
Warning: Overriding vetoes to perform a giveback can
be disruptive.
NodeA_data01 Not attempted yet
2 entries were displayed.
使用 故障模块名称并 查看下表、以获取故障排除文章的链接。
解决方案
下面列出了常见否决及其故障排除方法:
否决 | 故障模块名称 | 解决方案 |
---|---|---|
AutoSupport |
autosupport |
|
磁盘清单 |
disk_Inventory |
|
转储/还原 |
dump |
|
密钥管理器 |
keymanager |
|
锁定管理器 |
lock_manager |
|
RAID |
raid |
|
Snapmirror |
复制引擎 |