问题描述
- 升级到ONTAP 9.15.1后、EMS报告"
ClusterSwitchConnectionDegraded_Alert
":
Fri Dec 20 19:11:41 +0100 [CLUSTER-01: cshmd: hm.alert.raised:alert]: Alert Id = ClusterSwitchConnectionDegraded_Alert , Alerting Resource = CLUSTER-01 raised by monitor ethernet-switch
另外、 "
SwitchIslIfDownWarn_Alert
":
Mon Dec 23 16:14:20 +0100 [CLUSTER-01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchIslIfDownWarn_Alert , Alerting Resource = SWITCH-02(FOC2228R09J)/port-channel1 raised by monitor ethernet-switch
Mon Dec 23 16:14:20 +0100 [CLUSTER-01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchIslIfDownWarn_Alert , Alerting Resource = SWITCH-02(FOC2228R09J)/Ethernet1/31 raised by monitor ethernet-switch
Mon Dec 23 16:14:20 +0100 [CLUSTER-01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchIslIfDownWarn_Alert , Alerting Resource = SWITCH-02(FOC2228R09J)/Ethernet1/32 raised by monitor ethernet-switch
Mon Dec 23 16:15:13 +0100 [CLUSTER-01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchInfoUpdateFailure_Alert , Alerting Resource = SWITCH-01(FOC2228R0Q4) raised by monitor ethernet-switch
Mon Dec 23 16:15:33 +0100 [CLUSTER-01: cshmd: hm.alert.cleared:notice]: Alert Id = SwitchInfoUpdateFailure_Alert , Alerting Resource = SWITCH-01(FOC2228R0Q4) cleared by monitor ethernet-switch
- 但是、设备发现功能会报告这两个交换机没有任何问题