跳转到主内容

已针对链路聚合报告ClusterIfIslDownWarn_Alert警告

Views:
5
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches<a>2009年24月54日</a>
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9.10.1P4
  • FAS - AFF 系统
  • CN1610集群网络交换机

问题描述

  • 系统间歇性报告以下类型的警告
HA Group Notification (Health Monitor process cshm: ClusterIfIslDownWarn_Alert[XXXXXXXXXXX/ Link Aggregate 1]) ALERT
  • 构成链路聚合的端口错误显示在的输出中 system health alert show
Cluster::> system health alert show
 
Node: Node-01
Resource: Link Aggregate 1
Severity: Major
Indication Time: Wed Aug 17 05:41:50 2022
Suppress: false
Acknowledge: false
Probable Cause: The cable used to connect switch "Switch01/
Link Aggregate 1" to the ISL port might be faulty.
For the port-channel, please check each individual link.
Possible Effect: Cluster redundancy might be lost.
Corrective Actions:
1) Check whether the cable is fully inserted into the interface port on both ends.
2) Reconnect the ISL port using another cable. After
reconnecting it, verify whether the link of the ISL
port is up by executing the commands per the switch
configuration guide or by checking whether the Link
status LED is on.
 
  • 受影响的端口为 0/13 - 0/16、即集群网络交换机之间的交换机间链路(ISL)
  • show port all 交换机上的输出确认端口均已物理关闭
Admin   Physical  Physical  Link  Link   LACP  Actor
Intf    Type  Mode    Mode    Status   Status Trap   Mode  Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/1        Enable   10G Full  10G Full  Up   Enable  Enable long
--More-- or (q)uit
 
0/2        Enable   10G Full  10G Full  Up   Enable  Enable long
0/3        Enable   10G Full  10G Full  Up   Enable  Enable long
0/4        Enable   10G Full        Down  Enable  Enable long
0/5        Enable   10G Full        Down  Enable  Enable long
0/6        Enable   10G Full        Down  Enable  Enable long
0/7        Enable   10G Full        Down  Enable  Enable long
0/8        Enable   10G Full        Down  Enable  Enable long
0/9        Enable   10G Full        Down  Enable  Enable long
0/10       Enable   10G Full        Down  Enable  Enable long
0/11       Enable   10G Full        Down  Enable  Enable long
0/12       Enable   10G Full        Down  Enable  Enable long
0/13    PC Mbr Enable   10G Full       Down  Enable  Enable long
0/14    PC Mbr Enable   10G Full       Down  Enable  Enable long
0/15    PC Mbr Enable   10G Full       Down  Enable  Enable long
0/16    PC Mbr Enable   10G Full       Down  Enable  Enable long

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.