已针对链路聚合报告ClusterIfIslDownWarn_Alert警告
适用场景
- ONTAP 9.10.1P4
- FAS - AFF 系统
- CN1610集群网络交换机
问题描述
- 系统间歇性报告以下类型的警告
HA Group Notification (Health Monitor process cshm: ClusterIfIslDownWarn_Alert[XXXXXXXXXXX/ Link Aggregate 1]) ALERT
- 构成链路聚合的端口错误显示在的输出中
system health alert show
Cluster::> system health alert show
Node: Node-01
Resource: Link Aggregate 1
Severity: Major
Indication Time: Wed Aug 17 05:41:50 2022
Suppress: false
Acknowledge: false
Probable Cause: The cable used to connect switch "Switch01/
Link Aggregate 1" to the ISL port might be faulty.
For the port-channel, please check each individual link.
Possible Effect: Cluster redundancy might be lost.
Corrective Actions:
1) Check whether the cable is fully inserted into the interface port on both ends.
2) Reconnect the ISL port using another cable. After
reconnecting it, verify whether the link of the ISL
port is up by executing the commands per the switch
configuration guide or by checking whether the Link
status LED is on.
- 受影响的端口为
0/13 - 0/16
、即集群网络交换机之间的交换机间链路(ISL) show port all
交换机上的输出确认端口均已物理关闭
Admin Physical Physical Link Link LACP Actor
Intf Type Mode Mode Status Status Trap Mode Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/1 Enable 10G Full 10G Full Up Enable Enable long
--More-- or (q)uit
0/2 Enable 10G Full 10G Full Up Enable Enable long
0/3 Enable 10G Full 10G Full Up Enable Enable long
0/4 Enable 10G Full Down Enable Enable long
0/5 Enable 10G Full Down Enable Enable long
0/6 Enable 10G Full Down Enable Enable long
0/7 Enable 10G Full Down Enable Enable long
0/8 Enable 10G Full Down Enable Enable long
0/9 Enable 10G Full Down Enable Enable long
0/10 Enable 10G Full Down Enable Enable long
0/11 Enable 10G Full Down Enable Enable long
0/12 Enable 10G Full Down Enable Enable long
0/13 PC Mbr Enable 10G Full Down Enable Enable long
0/14 PC Mbr Enable 10G Full Down Enable Enable long
0/15 PC Mbr Enable 10G Full Down Enable Enable long
0/16 PC Mbr Enable 10G Full Down Enable Enable long