问题
- 系统间歇性报告以下类型的警告
HA Group Notification (Health Monitor process cshm: ClusterIfIslDownWarn_Alert[XXXXXXXXXXX/ Link Aggregate 1]) ALERT- 构成链路聚合的端口的错误显示在
system health alert show的输出中
Cluster::> system health alert showNode: Node-01Resource: Link Aggregate 1Severity: MajorIndication Time: Wed Aug 17 05:41:50 2022Suppress: falseAcknowledge: falseProbable Cause: The cable used to connect switch "Switch01/Link Aggregate 1" to the ISL port might be faulty.For the port-channel, please check each individual link.Possible Effect: Cluster redundancy might be lost.Corrective Actions:1) Check whether the cable is fully inserted into the interface port on both ends.2) Reconnect the ISL port using another cable. Afterreconnecting it, verify whether the link of the ISLport is up by executing the commands per the switchconfiguration guide or by checking whether the Linkstatus LED is on.- 受影响的端口是
0/13 - 0/16,即集群网络交换机之间的交换机间链路 (ISL) - 交换机上
show port all的输出确认端口全部物理关闭
Admin Physical Physical Link Link LACP ActorIntf Type Mode Mode Status Status Trap Mode Timeout--------- ------ --------- ---------- ---------- ------ ------- ------ --------0/1 Enable 10G Full 10G Full Up Enable Enable long--More-- or (q)uit0/2 Enable 10G Full 10G Full Up Enable Enable long0/3 Enable 10G Full 10G Full Up Enable Enable long0/4 Enable 10G Full Down Enable Enable long0/5 Enable 10G Full Down Enable Enable long0/6 Enable 10G Full Down Enable Enable long0/7 Enable 10G Full Down Enable Enable long0/8 Enable 10G Full Down Enable Enable long0/9 Enable 10G Full Down Enable Enable long0/10 Enable 10G Full Down Enable Enable long0/11 Enable 10G Full Down Enable Enable long0/12 Enable 10G Full Down Enable Enable long0/13 PC Mbr Enable 10G Full Down Enable Enable long0/14 PC Mbr Enable 10G Full Down Enable Enable long0/15 PC Mbr Enable 10G Full Down Enable Enable long0/16 PC Mbr Enable 10G Full Down Enable Enable long