跳转到主内容

Vifmgr收到OOQ并显示重复IP错误

Views:
1
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
perf<a>2009348582</a>
Last Updated:

适用场景

ONTAP 9

问题描述

  • 由于vifmgr出现问题、已迁移LIF
  • Vifmgr收到OOQ并显示重复IP错误

EMS :

[?] Sat Oct 22 20:18:18 +0900 [node2: kernel: netinet.ethr.duplct.ipAdrr:error]: Duplicate IP address xx.xx.xxx.x!! sent from Ethernet address: 02:a0:98:a3:44:4d.
[?] Sat Oct 22 20:18:18 +0900 [node2: kernel: netinet.ethr.duplct.ipAdrr:error]: Duplicate IP address xx.xxx.xx.xxx!! sent from Ethernet address: 02:a0:98:a3:44:51.
[?] Sat Oct 22 20:18:18 +0900 [node2: kernel: netinet.ethr.duplct.ipAdrr:error]: Duplicate IP address xx.xxx.xx.xxx!! sent from Ethernet address: 02:a0:98:a3:44:51.
[?] Sat Oct 22 20:18:19 +0900 [node2: kernel: netinet.ethr.duplct.ipAdrr:error]: Duplicate IP address xx.xx.x.xx!! sent from Ethernet address: 02:a0:98:a3:44:52.
[?] Sat Oct 22 20:18:19 +0900 [node2: kernel: netinet.ethr.duplct.ipAdrr:error]: Duplicate IP address xx.xxx.xx.xxx!! sent from Ethernet address: 02:a0:98:a3:44:51.
[?] Sat Oct 22 20:18:19 +0900 [node2: kernel: netinet.ethr.duplct.ipAdrr:error]: Duplicate IP address xx.xx.xx.x!! sent from Ethernet address: 02:a0:98:a3:44:4d.
[?] Sat Oct 22 20:18:19 +0900 [node2: kernel: netinet.ethr.duplct.ipAdrr:error]: Duplicate IP address xx.x.xx.xxx!! sent from Ethernet address: 02:a0:98:a3:44:4d.
[?] Sat Oct 22 20:18:19 +0900 [node2: kernel: netinet.ethr.duplct.ipAdrr:error]: Duplicate IP address xxx.xxx.xx.xxx!! sent from Ethernet address: 02:a0:98:a3:44:4d.
[?] Sat Oct 22 20:18:19 +0900 [node2: kernel: netinet.ethr.duplct.ipAdrr:error]: Duplicate IP address xxx.xxx.xx.xxx!! sent from Ethernet address: 02:a0:98:a3:44:4d.
[?] Sat Oct 22 20:18:19 +0900 [node2: kernel: netinet.ethr.duplct.ipAdrr:error]: Duplicate IP address xx.xxx.xx.xxx!! sent from Ethernet address: 02:a0:98:a3:44:51.
[?] Sat Oct 22 20:18:37 +0900 [node2: wafl_exempt03: ems.engine.suppressed:debug]: Event 'wafl.vol.runningOutOfInodes' suppressed 1039 times in last 1822 seconds.
[?] Sat Oct 22 20:18:37 +0900 [node2: wafl_exempt03: wafl.vol.runningOutOfInodes:error]: The file system on Volume sbc_sdsvgdc_d@vserver:ee6b63bc-04c7-11e9-b2c7-00a098a3443f is using 80 percent or more of the files that can be contained on the volume.
[?] Sat Oct 22 20:18:40 +0900 [node2: vifmgr: vifmgr.lifBeingRemoved:notice]: LIF OC1_N2_PIH_data (on virtual server 24), IP address xx.xx.x.xx, is being removed from node node2, port a0a-47.
[?] Sat Oct 22 20:18:41 +0900 [node2: vifmgr: vifmgr.lifBeingRemoved:notice]: LIF OC1_N2_SDS_data (on virtual server 4), IP address xx.xxx.xx.xxx, is being removed from node node2, port a1a-711.
[?] Sat Oct 22 20:18:41 +0900 [node2: vifmgr: vifmgr.lifBeingRemoved:notice]: LIF ON3_SDS01_data (on virtual server 15), IP address xx.xxx.xx.xxx, is being removed from node node2, port a1a-711.
[?] Sat Oct 22 20:18:41 +0900 [node2: vifmgr: vifmgr.lifBeingRemoved:notice]: LIF ON4_SDS01_data (on virtual server 17), IP address xx.xx.xx.xxx, is being removed from node node2, port a1a-711.
[?] Sat Oct 22 20:18:41 +0900 [node2: vifmgr: vifmgr.lifBeingRemoved:notice]: LIF OC1_N2_PORTAL_data (on virtual server 31), IP address xx.xxx.xx.xxx, is being removed from node node2, port a1a-711.
[?] Sat Oct 22 20:18:41 +0900 [node2: vifmgr: vifmgr.lifBeingRemoved:notice]: LIF OC1_N2_ETCn_data (on virtual server 6), IP address xxx.xxx.xx.xxx, is being removed from node node2, port a2a-132.
[?] Sat Oct 22 20:18:41 +0900 [node2: vifmgr: vifmgr.lifBeingRemoved:notice]: LIF ON4_ETC01_data (on virtual server 16), IP address xxx.xxx.xx.xxx, is being removed from node node2, port a2a-132.
[?] Sat Oct 22 20:18:41 +0900 [node2: vifmgr: vifmgr.lifBeingRemoved:notice]: LIF ON4_SWS01_data (on virtual server 18), IP address xx.xx.xx.x, is being removed from node node2, port a2a-2002.
[?] Sat Oct 22 20:18:41 +0900 [node2: vifmgr: vifmgr.lifBeingRemoved:notice]: LIF ON4_SCG01_data (on virtual server 20), IP address xx.xx.xxx.x, is being removed from node node2, port a2a-2004.
[?] Sat Oct 22 20:18:41 +0900 [node2: vifmgr: vifmgr.lifBeingRemoved:notice]: LIF ON4_CARD01_data (on virtual server 19), IP address xx.x.xx.xxx, is being removed from node node2, port a2a-21.

vifmgr:

00000015.003969f2 22f47aea Sat Oct 22 2022 20:17:04 +09:00 [kern_vifmgr:info:6697] ******* Secondary OOQ mtrace dump BEGIN *********

00000015.00396bbc 22f47b89 Sat Oct 22 2022 20:17:18 +09:00 [kern_vifmgr:info:6697] Notice: online_status_callback: RDB unit is offline
00000015.00399db8 22f47e39 Sat Oct 22 2022 20:18:27 +09:00 [kern_vifmgr:info:6697] [0x809b9be00] [EventMgr::unitOffline] Setting VifMgr operational status as OOQ
00000015.00399db9 22f47e39 Sat Oct 22 2022 20:18:27 +09:00 [kern_vifmgr:info:6697] [0x809b9be00] [FailoverMgr::localNodeDown] VifMgr on node node2 is now out of quorum.

00000015.0039a418 22f47e8f Sat Oct 22 2022 20:18:39 +09:00 [kern_vifmgr:info:6697] [0x80ac6a200] [DelayNotice::~DelayNotice] long-running operation (L2PingHealthMonitor::LocalReachabilityData::initBroadcastDomainData): 118118 milliseconds elapsed (> 5000)
00000015.0039a9e7 22f47ec3 Sat Oct 22 2022 20:18:41 +09:00 [kern_vifmgr:info:6697] [0x80af33800] [VserverCache::get_vserver_name] Failed to look up name for vserver id 4294967293: Timeout: Operation "vserver_info_iterator::get_imp()" took longer than 2 seconds to complete [from vifmgr on node "node2" (VSID: -1) to mgwd at 127.0.0.1]
00000015.0039a9e9 22f47ec3 Sat Oct 22 2022 20:18:41 +09:00 [kern_vifmgr:info:6697] [0x80af2de00] [VserverCache::get_vserver_name] Failed to look up name for vserver id 4294967293: Timeout: Operation "vserver_info_iterator::get_imp()" took longer than 2 seconds to complete [from vifmgr on node "node2" (VSID: -1) to mgwd at 127.0.0.1]
00000015.0039a9eb 22f47ec3 Sat Oct 22 2022 20:18:42 +09:00 [kern_vifmgr:info:6697] [0x809b9be00] [EventMgr::workerThreadMain] long-running event: event="Unit is offline", time=14926 ms
00000015.0039aa5b 22f47ec3 Sat Oct 22 2022 20:18:43 +09:00 [kern_vifmgr:info:6697] [0x80af2de00] [VserverCache::get_vserver_name] Failed to look up name for vserver id 4294967293: Timeout: Operation "vserver_info_iterator::get_imp()" took longer than 2 seconds to complete [from vifmgr on node "node2" (VSID: -1) to mgwd at 127.0.0.1]
00000015.0039b07e 22f47ef9 Sat Oct 22 2022 20:18:51 +09:00 [kern_vifmgr:info:6697] [0x80af36500] [vifmgr_virtual_interface_iterator::get_imp] Failed to successfully calculate operational status: Timeout: Operation "vserver_info_iterator::get_imp()" took longer than 25 seconds to complete [from vifmgr on node "node2" (VSID: -1) to mgwd at 127.0.0.1]
00000015.0039b07f 22f47ef9 Sat Oct 22 2022 20:18:51 +09:00 [kern_vifmgr:info:6697] [0x80adba000] [vifmgr_virtual_interface_iterator::get_imp] Failed to successfully calculate operational status: Timeout: Operation "vserver_info_iterator::get_imp()" took longer than 25 seconds to complete [from vifmgr on node "node2" (VSID: -1) to mgwd at 127.0.0.1]
00000015.0039b081 22f47ef9 Sat Oct 22 2022 20:18:51 +09:00 [kern_vifmgr:info:6697] [0x80ac67500] [vifmgr_virtual_interface_iterator::get_imp] Failed to successfully calculate operational status: Timeout: Operation "vserver_info_iterator::get_imp()" took longer than 25 seconds to complete [from vifmgr on node "node2" (VSID: -1) to mgwd at 127.0.0.1]
00000015.0039b083 22f47ef9 Sat Oct 22 2022 20:18:51 +09:00 [kern_vifmgr:info:6697] [0x80ac75600] [vifmgr_virtual_interface_iterator::get_imp] Failed to successfully calculate operational status: Timeout: Operation "vserver_info_iterator::get_imp()" took longer than 25 seconds to complete [from vifmgr on node "node2" (VSID: -1) to mgwd at 127.0.0.1]

  • 根聚合只有一个磁盘、在发生问题时、该磁盘处于繁忙状态

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.