SP 固件 3.0.1P1 与用于 SwitchAPI 的 Data ONTAP 不兼容
适用场景
- SP版本 3.0.1p
- FAS 80
- ONTAP 9
- AF-A8080
问题描述
- 在主板更换后、无法使用管理员凭据在恢复后登录到服务处理器。
- SP运行的固件版本为3.0.1p、此版本仅与7-模式兼容。
- 从集群手动更新SP失败、并显示以下消息
Cluster::*> system service-processor image update -node Node-01 -baseline true
Note: Firmware update will need to reboot the SP on completion. If your console connection is through the SP,
it will be disconnected
Do you want to proceed with the firmware update ? {y|n}: y
Error: command failed: Pre-update Check failed: SP is not Cluster Services capable.
- EMS日志将报告以下警报
Wed Feb 23 02:32:16 +0530 [Node-01: splog_main: splog.running.normally:info]: Process splogd is operating normally.
Wed Feb 23 02:32:16 +0530 [Node-01: sp_applications_init: sp.firmware.upgrade.reqd:alert]: The SP firmware 3.0.1P1 is incompatible with Data ONTAP for SwitchAPI.
- ONTAP在启动过程中报告以下错误消息:
Oct 07 18:27:07 [Node-01:nvram.battery.sensor.unreadable:EMERGENCY]: The NVRAM battery state cannot be determined because the 'Bat Initial FCC' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
Oct 07 18:27:37 [Node-01:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Initial FCC' unreadable) CRITICAL.