适用场景

  • ONTAP 9
  • 运行状况监控进程cshm:SwitchFanNotOperational _Alert、请致电主目录

事件摘要

如果未检测到风扇电源且风扇状态显示为非正常运行、则会发送SwitchFanNotOperational _Alert。 

验证

自动通报事件

HA Group Notification from Node Name (Health Monitor process cshm: SwitchFanNotOperational_Alert[Switch Name(Switch Serial Number)/Fan Module-3]) ALERT

EMS日志

event log show -severity * -message-name callhome*

[Node Name: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchFanNotOperational_Alert[Switch Name(Switch Serial Number)/Fan Module-3].

命令行

system health alert show -node <node name> -monitor cluster-switch -alert-id SwitchFanNotOperational_Alert

            Node: Node01
          Monitor: cluster-switch
       Class of Alert: SwitchFanNotOperational_Alert
     Severity of Alert: Major
       Probable Cause: Out_of_service
Probable Cause Description: "Fan Module-3" on switch "Switch Name(Switch Name)" is not functioning properly.
      Possible Effect: Cooling of switch "Switch Name(Serial Number)" might be degraded.
     Corrective Actions: 1) Use the switch CLI to verify that the fan is functioning at the expected speed.                      2) Replace the fan, if it is not operational.

交换机日志输出:

switch_name# show environment fan detail

Fan:
---------------------------------------------------------------------------
Fan        Model         Hw    Direction     Status
---------------------------------------------------------------------------
Fan1(sys_fan1)  NXA-FAN-30CFM-F    --    back-to-front  Failure
Fan2(sys_fan2)  NXA-FAN-30CFM-F    --    back-to-front   Ok

Fan:
------------------------------------------------------------------
Fan Name      Fan Num   Fan Direction   Speed(%)  Speed(RPM)
------------------------------------------------------------------
Fan1(sys_fan1)    fan1   back-to-front   0     0
Fan1(sys_fan1)    fan2   back-to-front   100     11563

解决方法

  1. 验证维护是否在AutoSupport自动通报时间戳期间进行或已计划维护。
  2. 验证数据中心内是否有电源问题描述。
  3. 验证风扇是否安装正确。
    • 如果可能、重新拔插受影响的风扇。

 

如果确认 有故障、请更换风扇:

  • 对于Broadcom交换机、请联系 Broadcom 以获得帮助
  • 对于Cisco交换机、请联系 Cisco 以获得帮助
  • 对于NVIDIA交换机、请联系 NVIDIA 以获得帮助
  • 对于CN1610交换机、请联系 NetApp技术支持 以获得帮助

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.