适用场景

  • AFF A400
  • FAS8700
  • FAS8300
  • 意外接管(无检测信号警报)

问题描述

  • 意外接管节点:
[node_name_1: cf_main: cf.fsm.takeover.noHeartbeat:alert]: Failover monitor: Takeover initiated after no heartbeat was detected from the partner node.
  • 报告的检测信号消息:

[node_name_1: cf_main: fm_lastHeartbeatInfo_1:debug]: params: {'time_since_firmware_rcvd': '5000', 'time_since_htbt_read_attempt_ic': '1000', 'time_since_mb_upd_minor_seq': '13', 'time_since_mb_upd_major_seq': '520405022', 'time_since_htbt_read_success_ic': '6000', 'current_time': '520650179', 'time_since_htbt_read_success_mb': '4029', 'time_since_ic_upd_major_seq': '520407022', 'time_since_htbt_write_ic': '0', 'time_since_first_htbt_write_mb_drop': '259840013', 'time_since_htbt_write_mb': '13', 'time_since_ic_upd_minor_seq': '0', 'mb_htbt_drop_count': '10', 'time_since_recent_htbt_write_mb_drop': '259837513', 'time_since_firmware_written': '0', 'time_since_htbt_read_upd_seq_ic': '6000', 'partner_minor_seq_num_mb': '728568', 'time_since_firmware_read': '6979', 'partner_minor_seq_num_ic': '728567', 'partner_major_seq_num_ic': '1669711236', 'time_since_htbt_read_upd_seq_mb': '4029', 'partner_major_seq_num_mb': '1669711236', 'time_since_htbt_read_attempt_mb': '4029'}
[node_name_1: cf_main: fm_lastHeartbeatInfo_1:debug]: params: {'time_since_firmware_rcvd': '20000', 'time_since_htbt_read_attempt_ic': '1000', 'time_since_mb_upd_minor_seq': '13', 'time_since_mb_upd_major_seq': '520420022', 'time_since_htbt_read_success_ic': '21000', 'current_time': '520665179', 'time_since_htbt_read_success_mb': '867', 'time_since_ic_upd_major_seq': '520422022', 'time_since_htbt_write_ic': '0', 'time_since_first_htbt_write_mb_drop': '259855013', 'time_since_htbt_write_mb': '13', 'time_since_ic_upd_minor_seq': '0', 'mb_htbt_drop_count': '10', 'time_since_recent_htbt_write_mb_drop': '259852513', 'time_since_firmware_written': '0', 'time_since_htbt_read_upd_seq_ic': '21000', 'partner_minor_seq_num_mb': '728568', 'time_since_firmware_read': '21979', 'partner_minor_seq_num_ic': '728567', 'partner_major_seq_num_ic': '1669711236', 'time_since_htbt_read_upd_seq_mb': '19029', 'partner_major_seq_num_mb': '1669711236', 'time_since_htbt_read_attempt_mb': '867'}

  • 未找到任何Panic消息。
  • 在某些情况下、可能会填充SSRAM日志:

SRAM record type(CPU) from Data ONTAP: socket(0) core(8) bank(6)
SRAM record type(LOG) from Data ONTAP: IIO MCE Root Bus(23), Device(0), Function(0), Segment(0).

  • 节点重新启动将完成恢复并继续正常工作。
  • 可能发生多次使用相同签名的重新启动。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.