适用场景

  • AFF A900、AFF A800、AFF A700、AFF A400、AFF A320
  • 按照布线最佳实践添加了新的NS224磁盘架并正常工作 
  • 存储配置会从直连存储更改为交换机连接存储
  • Cisco Nexus 3232C或9336C-x2交换机

问题描述

  • NSMANSMB模块的运行状况警报

Monitor          node-connect
Alert ID         NoPathToNSMA_Alert
Alerting Resource    01234567890123456789
Subsystem         SAS-connect
Indication Time      Sun May 08 21:34:51 2022
Perceived Severity    Major
AutoSupport Triggered   true
Probable Cause      Cable_tamper
Corrective Actions   1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
           2. Connect controller amsnapc01n01 to module A and module B of shelf 1.2.

  • 系统会定期发出和清除警报: 

::>event log show -event hm.alert*
Time                Node      Severity   Event
------------------- --------  --------   ---------------------------
4/22/2022 16:12:01  node_name-1  NOTICE     hm.alert.cleared: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
4/22/2022 15:42:00  node_name-2  ALERT      hm.alert.raised: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect

  • 重复的EMS消息:

...
[node_name-1: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-1: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-1: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect
[node_name-1: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect

...
[node_name-2: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-2: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect
[node_name-2: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-2: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect

  • system switch ethernet show输出中未列出任何存储交换机。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.