从节点看到 NoPathToNSMA_Alert,从伙伴节点看到 NoPathToNSMB_Alert
适用于
- NS224盘架
- ONTAP 9
问题描述
- 在
sysconfig -a
日志中,System Storage Configuration: 显示为Single-Path HA.
- 执行
Takeover/Giveback
时,出现以下错误。
Port e4a on controller Node2 is connected to port e0b on module A of shelf 1.0.
Corrective Actions:
1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
2. Connect e4a to e0a on either module of shelf 1.0.
NSMA
和NSMB
模块的健康警报。
Node:node-1
Monitor : node-connect
Alert ID :NoPathToNSMA_Alert
Alerting Resource :*****
Subsystem : SAS-connect
Indication Time : Fri Feb 28 15:03:15 2025
Perceived Severity : Major
Probable Cause : Cable_tamper
Corrective Actions :
1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
2. Connect controller Node1 to module A and module B of shelf 1.0.
- 或者,虽然连接到 NS224 盘架的 HA 对从
sysconfig -a
nodeshell 命令输出中显示为多路径,但会看到以下警报:
节点 01 显示
NoPathToNSMA_Alert
节点 02 显示
NoPathToNSMB_Alert