问题描述

  • sysconfig -a 日志中,System Storage Configuration: 显示为 Single-Path HA.
  • 执行 Takeover/Giveback 时,出现以下错误。

Port e4a on controller Node2 is connected to port e0b on module A of shelf 1.0.
Corrective Actions:
   1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
   2. Connect e4a to e0a on either module of shelf 1.0.

  • NSMANSMB 模块的健康警报。

Node:node-1
Monitor : node-connect
Alert ID  :NoPathToNSMA_Alert
Alerting Resource  :*****
Subsystem      : SAS-connect
Indication Time   : Fri Feb 28 15:03:15 2025
Perceived Severity :  Major
Probable Cause   : Cable_tamper
Corrective Actions :
1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
2. Connect controller Node1 to module A and module B of shelf 1.0.

  • 或者,虽然连接到 NS224 盘架的 HA 对从 sysconfig -a nodeshell 命令输出中显示为多路径,但会看到以下警报:
节点 01 显示 NoPathToNSMA_Alert
节点 02 显示 NoPathToNSMB_Alert

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.