从节点看到 NoPathToNSMA_Alert,从伙伴节点看到 NoPathToNSMB_Alert
适用于
- NS224盘架
- ONTAP 9
问题描述
- 在
sysconfig -a日志中,System Storage Configuration: 显示为Single-Path HA. - 执行
Takeover/Giveback时,出现以下错误。
Port e4a on controller Node2 is connected to port e0b on module A of shelf 1.0.
Corrective Actions:
1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
2. Connect e4a to e0a on either module of shelf 1.0.
NSMA和NSMB模块的健康警报。
Node:node-1
Monitor : node-connect
Alert ID :NoPathToNSMA_Alert
Alerting Resource :*****
Subsystem : SAS-connect
Indication Time : Fri Feb 28 15:03:15 2025
Perceived Severity : Major
Probable Cause : Cable_tamper
Corrective Actions :
1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
2. Connect controller Node1 to module A and module B of shelf 1.0.
- 或者,虽然连接到 NS224 盘架的 HA 对从
sysconfig -anodeshell 命令输出中显示为多路径,但会看到以下警报:
节点 01 显示
NoPathToNSMA_Alert节点 02 显示
NoPathToNSMB_Alert