跳转到主内容

NSM100 DIMMは不明であり、モジュールの背後にディスクが認識されない

Views:
4
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009791359</a>
Specialty:
hw
Last Updated:

環境

NSM100

問題

  • NS224シェルフに障害LEDがある
  • storage show fault -v NSM100のDIMMに関する次のエラーが出力に表示されます。

DIMM:
Element Status Status Bytes Status Descriptions
1 [NSM100 A] : OK 01,00,00,00
2 [NSM100 A] : OK 01,00,00,00
3 [NSM100 A] : OK 01,00,00,00
4 [NSM100 A] : UNKNOWN 06,00,00,00
5 [NSM100 B] : OK 01,00,00,00
6 [NSM100 B] : OK 01,00,00,00
7 [NSM100 B] : OK 01,00,00,00
8 [NSM100 B] : OK 01,00,00,00

  • このモジュールへの両方のストレージポートが稼働していますが、このモジュールへのパスまたはノードの背後でディスクが認識されていません。

System Storage Configuration: Mixed-Path HA

slot 0: Dual 40G/100G Ethernet Controller CX5
e0c MAC Address: a0:11:22:33:aa:44 (auto-100g_cr4-fd-up)
QSFP Vendor: Amphenol
QSFP Part Number: 112-00573
QSFP Serial Number: APF123456789
e0d MAC Address: a0:11:22:33:aa:44 (auto-100g_cr4-fd-up)

e5b MAC Address: b0:aa:a1:b2:b3:44 (auto-100g_cr4-fd-up)
QSFP Vendor: Molex
QSFP Part Number: 112-00574
QSFP Serial Number: 93A123456789
Device Type: CX5 PSID(NAP0000001002)
Firmware Version: 16.26.4012
Part Number: MCX516A-CCAT_C21
Hardware Revision: B2
Serial Number: MT12345657890         <<<< Missing disks behind adapters
slot 0: Virtual iSCSI Host Adapter 0m

 

  • どちらの接続にも誤って接続されているディスクがこのモジュールに接続されています device-discovery 。このモジュールはASUPの出力で確認できます。

NetApp NS224.NSM100.SH00.A (v.0203)
NetApp NS224.NSM100.SH00.A (v.0203)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • 这篇文章对您有帮助吗?