问题描述

  • 为一个NSM100模块报告的错误:
::*> storage shelf show -errors Shelf Name: 1.12 Serial Number: XXXXXXXXXXXXXXX Error Type Description ------------------ --------------------------- Bootdevice Boot device "2" error detected. Coinbattery Coin cell battery "2" error detected. DIMM DIMM "5" error detected. DIMM is located in the DIMM slot 1 in the bottom shelf module (B). DIMM DIMM "6" error detected. DIMM is located in the DIMM slot 2 in the bottom shelf module (B). DIMM DIMM "7" error detected. DIMM is located in the DIMM slot 3 in the bottom shelf module (B). DIMM DIMM "8" error detected. DIMM is located in the DIMM slot 4 in the bottom shelf module (B). Fan Error detected in cooling fan "11". Fan is located in the inlet FAN of fan module 1 in the bottom shelf module (B). Fan Error detected in cooling fan "12". Fan is located in the inlet FAN of fan module 2 in the bottom shelf module (B). Fan Error detected in cooling fan "13". Fan is located in the inlet FAN of fan module 3 in the bottom shelf module (B). Fan Error detected in cooling fan "14". Fan is located in the inlet FAN of fan module 4 in the bottom shelf module (B). Fan Error detected in cooling fan "15". Fan is located in the inlet FAN of fan module 5 in the bottom shelf module (B). Fan Error detected in cooling fan "16". Fan is located in the outlet FAN of fan module 1 in the bottom shelf module (B). Fan Error detected in cooling fan "17". Fan is located in the outlet FAN of fan module 2 in the bottom shelf module (B). Fan Error detected in cooling fan "18". Fan is located in the outlet FAN of fan module 3 in the bottom shelf module (B). Fan Error detected in cooling fan "19". Fan is located in the outlet FAN of fan module 4 in the bottom shelf module (B). Fan Error detected in cooling fan "20". Fan is located in the outlet FAN of fan module 5 in the bottom shelf module (B). Module Critical error detected in module "B". Power Critical condition is detected in storage shelf power supply unit "2". The unit might fail. Temperature Temperature reported by temperature sensor "12" exceeds the specifications for the disk shelf or its components. Temperature Temperature reported by temperature sensor "13" exceeds the specifications for the disk shelf or its components. Temperature Temperature reported by temperature sensor "14" exceeds the specifications for the disk shelf or its components. Temperature Temperature reported by temperature sensor "15" exceeds the specifications for the disk shelf or its components. Temperature Temperature reported by temperature sensor "16" exceeds the specifications for the disk shelf or its components. Temperature Temperature reported by temperature sensor "17" exceeds the specifications for the disk shelf or its components.
  • 将磁盘架固件升级到最新版本后、问题描述 仍会保留。
  • 在NSM100 B重新启动、重新安装和更换后、问题描述 仍然存在。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.