NIC端口已关闭
适用场景
ONTAP 9
问题描述
- NIC端口已关闭。
ifconfig -a
TX
受影响SFP的报告为-inf
。
e2b: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500
uuid: f8146927-4cad-11ec-b538-d039ea3780f8
options=ec07bb<RXCSUM,TXCSUM,VLAN_MTU,VLAN_HWTAGGING,JUMBO_MTU,VLAN_HWCSUM,TSO4,TSO6,LRO,VLAN_HWTSO,LINKSTATE,RXCSUM_IPV6,TXCSUM_IPV6>
capabilities=ec07bb<RXCSUM,TXCSUM,VLAN_MTU,VLAN_HWTAGGING,JUMBO_MTU,VLAN_HWCSUM,TSO4,TSO6,LRO,VLAN_HWTSO,LINKSTATE,RXCSUM_IPV6,TXCSUM_IPV6>
ether 40:a6:b7:71:20:79
media: Ethernet autoselect (autoselect <full-duplex>)
status: no carrier
supported media:
media autoselect
media 10GBase-SFI
media 1000Base-KX
media 10Gbase-LR
media 10Gbase-SR
media 10Gbase-Twinax
media 1000baseLX
media 1000baseSX
plugged: SFP/SFP+/SFP28 10G Base-SR (LC)
vendor: Intel Corp PN: FTLX8574D3BCV-IT SN: A4QAT70 DATE: 2020-12-19
module temperature: 21.67 C Voltage: 3.42 Volts
RX: 0.63 mW (-2.01 dBm) TX: 0.00 mW (-inf dBm)