NIC 端口在 ifstat 中看到 CRC 错误
适用于
- FAS / AFF 系统
- 网络适配器
问题描述
- ifstat 命令的输出在受影响的端口上显示高 CRC 错误: 
::> system node run -node <NODE_NAME> -command ifstat <PORT>
-- interface  e4a  (7 hours, 33 minutes, 13 seconds) --
RECEIVE
  Total frames:    10739k | Frames/second:     395  | Total bytes:     14537m
  Bytes/second:      534k | Total errors:     4921  | Errors/minute:      11 
  Total discards:      0  | Discards/minute:     0  | Multi/broadcast:   334k
  Non-primary u/c:     0  | CRC errors:       4921 | Runt frames:         0 
  Fragment:            0  | Long frames:         0  | Jabber:              0  
- 事件日志中报告了以下错误:
[Node-02: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e4a on node Node-02 is reporting a high number of observed CRC errors.
- IFCONFIG-VVVM可能显示 SFP Rx 功率低于预期:- e9a: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500- media: Ethernet autoselect <rxpause,txpause> (25GBase-SR <full-duplex,rxpause,txpause>)
 status: active- plugged: SFP/SFP+/SFP28 100GBASE-SR4 or 25GBASE-SR (LC)
 module temperature: 36.62 C voltage: 3.33 Volts
 lane 1: RX power: 0.08 mW (-11.10 dBm) TX bias: 8.02 mA
 - e9a: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500- media: Ethernet autoselect <rxpause,txpause> (25GBase-SR <full-duplex,rxpause,txpause>)
 status: active- plugged: SFP/SFP+/SFP28 100GBASE-SR4 or 25GBASE-SR (LC)
 module temperature: 38.38 C voltage: 3.33 Volts
 lane 1: RX power: 0.26 mW (-5.86 dBm) TX bias: 8.02 mA