从 SFP 切换到 DAC 电缆时 NIC 链接失败
适用于
- FAS9000
- ONTAP 9
- 网络接口卡 (NIC)
- 直接连接电缆 (DAC)
- 从 SFP 模块更换为 DAC
- NetApp Hardware Universe (HWU)
- X91143A: Qlogic EP8324 四端口 16Gb FC/10GbE PCIe CNA
问题描述
- 将 NIC 连接从 SFP 模块切换到 DAC 后,链路不会在特定端口上出现。
EMS 日志:[node-11:nblade1:netif.linkDown:info]: Ethernet e10a: Link down, check cable.
Sysconfig -a:
slot 10: Fibre Channel Target Host Adapter 10a (QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED>) Firmware rev: 8.9.0 Flash rev: 6.0.1 Host Port Addr: 000000 FC Nodename: 50:0a:XX:XX:XX:XX:XX:15 (500a012345678915) FC Portname: 50:0a:XX:XX:XX:XX:XX:15 (500a012345678915) Connection: No link Switch Port: Unknown SFP Vendor Name: Panduit Corp. SFP Vendor P/N: PSF2PZA2MBU SFP Vendor Rev: X6 SFP Serial No.: 212345678904 SFP Connector: Passive Copper SFP Capabilities: 10 Gbit/Sec