跳转到主内容

从 SFP 切换到 DAC 电缆时 NIC 链接失败

Views:
Visibility:
Public
Votes:
0
Category:
not set
Specialty:
not set
Last Updated:

适用于

  • FAS9000
  • ONTAP 9
  • 网络接口卡 (NIC)
  • 直接连接电缆 (DAC)
  • 从 SFP 模块更换为 DAC
  • NetApp Hardware Universe (HWU)
  • X91143A: Qlogic EP8324 四端口 16Gb FC/10GbE PCIe CNA

问题描述

  • 将 NIC 连接从 SFP 模块切换到 DAC 后,链路不会在特定端口上出现。

EMS 日志:
[node-11:nblade1:netif.linkDown:info]: Ethernet e10a: Link down, check cable.

Sysconfig -a:

slot 10: Fibre Channel Target Host Adapter 10a
         (QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED>)
         Firmware rev:    8.9.0
         Flash rev:      6.0.1
         Host Port Addr:   000000
         FC Nodename:     50:0a:XX:XX:XX:XX:XX:15 (500a012345678915)
         FC Portname:     50:0a:XX:XX:XX:XX:XX:15 (500a012345678915)
         Connection:     No link
         Switch Port:     Unknown
  SFP Vendor Name:  Panduit Corp. 
  SFP Vendor P/N:   PSF2PZA2MBU
  SFP Vendor Rev:   X6
  SFP Serial No.:   212345678904
  SFP Connector:    Passive Copper
  SFP Capabilities:  10 Gbit/Sec

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 