跳转到主内容

故障 LED 亮起,没有实际问题

Views:
40
Visibility:
Public
Votes:
0
Category:
fas-systems<a /><a /><a>2008616659 上的警示 LED</a>
Specialty:
hw
Last Updated:

适用场景

纯 AFF/FAS

问题描述

  • 警示 LED 亮起,即使没有实际问题。
  • 在某些情况下,由于组件出现故障, LED 亮起,在修复后仍保持亮起状态。

::> system health alert show
This table is currently empty.

::> system health status show
Status
---------------
ok

::> system health subsystem show
Subsystem      Health
----------------- ------------------
SAS-connect     ok
Environment     ok
Memory       ok
...

  • fru LED status 命令指示 LED 状态为 on 。例如: 
    • ONTAP OS 7- 模式
node*> fru_led status
Controller slot A: On (lit by Data ONTAP)
DIMM slot 1:     Off
DIMM slot 2:     Off
DIMM slot 3:     Off
DIMM-NV slot 1:   Off
PCI slot 1:     On
PCI slot 2:     Off
...
  • ONTAP OS 集群模式:
::*> system controller fru led show
Node          FRU Type   Bay Slot State   Lit By
--------------------- ----------- --- ---- ------- -------
node_name
            controller   A 1   on    SP
            ioxm      B 1   off    -
            pci       - 1   off    -
...

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.