磁盘故障—AutoSupport 消息
适用场景
- ONTAP 9
- CallHome.dsk.fault
- callhome.carrier.fault
- callhome.dsk.noio
- disk /aggr01/plex
HA Group Notification from ClusterA-01 (DISKS FAILED IN CARRIER Shelf 0, Bay 3, Model [], Carrier []) WARNING
HA Group Notification from ClusterA-01 (DISK FAILED Shelf 22, Bay 11, Model [], S/N []) ERROR
HA Group Notification from ClusterA-01 (DISK NOT RESPONDING) ERROR
HA Group Notification from ClusterA-01 (DISK NOT SPINNING) ERROR
HA Group Notification from ClusterA-01 (FILESYSTEM DISK FAILED Shelf 44, Bay 7, Model [], S/N []) ERROR
HA Group Notification from ClusterA-01 (FILESYSTEM DISK NOT RESPONDING) WARNING
HA Group Notification from ClusterA-01 (SPARE DISK FAILED Shelf 17, Bay 8, Model [], S/N []) ERROR
HA Group Notification from ClusterA-01 (SPARE DISK NOT RESPONDING) ERROR
事件摘要
磁盘驱动器发生故障时会出现此消息。
[node1: config_thread: callhome.dsk.fault:error]: Call home for DISK FAILED Shelf 1, Bay 1, Model [X###_######], S/N [#####]
[node1: config_thread: callhome.carrier.fault:error]: Call home for DISKS FAILED IN CARRIER Shelf 1, Bay -, Model [X###_#####], Carrier [########]
验证
命令行
- 运行
storage disk show -broken
::>storagediskshow -broken Original Owner: node1 Checksum Compatibility: block Drawer Usable Physical Disk Outage Reason HA Shelf Bay /Slot Chan Pool Type RPM Size Size --------------- ------------- --- ----- --- ------ ---- ------ ----- ------ -------- -------- 4.22.42 failed 2a 22 42 4/6 A FAILED FSAS 7200 8.89TB 8.91TB