跳转到主内容

Brocade G720 和 G610 switchshow 报告端口状态 Mod_Val

Views:
80
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用于

  • Brocade G720
  • Brocade G610
  • MetroCluster FC

问题

  • 观察 Flapping ISL。
  • switchshow 将端口状态报告为 Mod_Val

Index Port Address  Media Speed   State       Proto
==================================================
   0   0   050000   id    16G     Online      FC  
   1   1   050100   id    16G     Online      FC  
   2   2   050200   id    16G     Online      FC  
   3   3   050300   id    16G     Online      FC  
   4   4   050400   id    16G     Online      FC  
   5   5   050500   id    16G     Online      FC  
   6   6   050600   id    16G     Online      FC  
   7   7   050700   id    16G     Online      FC  
   8   8   050800   id    16G     Online      FC  
   9   9   050900   id    16G     Online      FC  
  10  10   050a00   id    16G     Online      FC  
  11  11   050b00   id    16G     Online      FC  
  12  12   050c00   id    16G     Online      FC  
  13  13   050d00   id    16G     Online      FC  
  14  14   050e00   id    16G     No_Light    FC  
  15  15   050f00   id    16G     No_Light    FC  
  16  16   051000   id    16G     No_Light    FC  
  17  17   051100   id    16G     No_Light    FC  
  18  18   051200   id    16G     No_Light    FC  
  19  19   051300   id    16G     No_Light    FC  
  20  20   051400   id   16G     Mod_Val     FC  
  21  21   051500   id    16G     Online      FC  
  22  22   051600   id    16G     No_Light    FC  
  23  23   051700   id    16G     No_Light    FC 

  • 应实施以下步骤来进一步隔离问题-
    • 使用 portdisable / portenable 命令切换端口
    • 将 SFP 模块与另一个已知良好的 SFP 进行更换。
    • 重新启动或重新启动交换机。

  • 如果上述隔离步骤无法解决此问题,请继续执行解决方案。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.