跳转到主内容

更换缆线后、ATto光纤桥FC端口上的同步丢失

Views:
12
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • ATto 6500N光纤桥接
  • ATto 7500N光纤桥接
  • ATto 7600N光纤桥接
 

问题描述

  • 报告了光纤桥接中FC端口的大量同步丢失

get FCPortErrors all

; Fibre Channel Error Counts
; Port | Link Failures | Sync Loss | Signal Loss | Invalid Tx | Invalid CRC
;==========================================================================
   1                 2          212            0          448             0
   2                 2           3             0            8             0

Ready.
====================================

  • 已更换受影响网桥端口和交换机之间的光缆。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.