尝试将调解器添加到MetroCluster系统时、出现"无法访问调解器"错误
- Views:
- 1
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- metrocluster<a>2009522058</a>
- Last Updated:
适用场景
- ONTAP 9
- MetroCluster IP
- ONTAP 调解器
问题描述
- 尝试向MetroCluster系统添加ONTAP调解器时报告错误:
ClusterA::> metrocluster configuration-settings mediator add -mediator-address 10.10.10.10
Adding the mediator and enabling Automatic Unplanned Switchover. It may take a few minutes to complete.
Please enter the username for the mediator: mediatoradmin
Please enter the password for the mediator:
Confirm the mediator password:
Creating mediator mailboxes...
Error: command failed: The request to reach the mediator failed during the add operation. Check if the mediator is reachable and then try the operation again.
- 在
/var/log/messages
Linux主机端、我们看到报告了重复的目标错误:
iscsi-scstd[990799]: duplicated target iqn.2012-05.local:mailbox.target.123456789-123456789-123456789:987654321-987654321-987654321-987654321-987654321:1