跳转到主内容

T6 卡端口在 MetroCluster IP 中出现故障,易受 CONTAP-204693 影响

Views:
212
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用于

  • ONTAP 9
  • MetroCluster IP
  •  双端口 40/100G 以太网 T62100-CR 卡
  • 未在 CONTAP-204693 的固定版本中

问题

  • AutoSupport 从节点生成:HA Group Notification from cl01-n01 (PARTNER DOWN, TAKEOVER IMPOSSIBLE ) EMERGENCY
  • 40/100G 以太网 T62100-CR 卡的两个端口在遇到致命错误后都出现故障:
Tue Mar 23 11:00:58 +0000 [MC2-N02: intr: netif.linkDown:info]: Ethernet e1a: Link down, check cable.
Tue Mar 23 11:00:58 +0000 [MC2-N02: intr: netif.linkDown:info]: Ethernet e1b: Link down, check cable.
Tue Mar 23 11:00:58 +0000 [MC2-N02: intr: netif.fatal.err:alert]: The network device in slot 1 encountered fatal error e1a/e1b.
  • 节点重新启动可能会在控制台上显示以下错误:

e5a/e5b (t6nex0): ! PL_PERR_CAUSE 0x19404 = 0x00000001, E 0x1fffe3ff, F 0xffffffff
e5a/e5b (t6nex0): ! [0x00000001] CIM
e5a/e5b (t6nex0): * PL_INT_CAUSE 0x1940c = 0x00100041, E 0x1fffe77d, F 0x00000000
e5a/e5b (t6nex0): * [0x00100000] MA
e5a/e5b (t6nex0): * [0x00000040] PL
e5a/e5b (t6nex0): * [0x00000001] CIM
e5a/e5b (t6nex0): ! MA_INT_CAUSE 0x77e0 = 0x00000002, E 0x00000007, F 0x00000006
e5a/e5b (t6nex0): ! MA_PARITY_ERROR_STATUS1 0x77f4 = 0x00020000, E 0x00000000, F 0xffffffff
e5a/e5b (t6nex0): ! PL_PL_INT_CAUSE 0x19430 = 0x00000018, E 0x00000010, F 0x00000010
e5a/e5b (t6nex0): ! [0x00000010] Fatal parity error
e5a/e5b (t6nex0): ? [0x00000008]
e5a/e5b (t6nex0): firmware reports adapter error: Crash (0xc014c010)

  • 节点重新启动后,端口可能会完全恢复或在短时间内再次关闭

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.