跳转到主内容

MetroCluster互连镜像显示DR已脱机启用

Views:
15
Visibility:
Public
Votes:
1
Category:
metrocluster
Specialty:
metrocluster<a>2009618716</a>
Last Updated:

适用场景

  • MetroCluster IP
  • 共享网络

问题描述

  • MetroCluster互连镜像显示正在脱机并启用灾难恢复、但所有其他配置显示已配置并启用
  • 远程集群镜像已脱机

cluster-01::*> metrocluster interconnect mirror show
  (metrocluster interconnect mirror show)
                          Mirror   Mirror
                  Partner Admin    Oper
Node Partner Name Type    Status   Status  Adapter Type   Status
---- ------------ ------- -------- ------- ------- ------ ------
cluster-01n01
     cluster-01n02
                  HA      enabled  online
                                           e0b     iWARP  Up
                                           e1b     iWARP  Up
     cluster-02n01
                  DR      enabled offline
                                           e0b     iWARP  Up
                                           e1b     iWARP  Up
     cluster-02n02
                  AUX     enabled offline
                                           e0b     iWARP  Up
                                           e1b     iWARP  Up
cluster-01n02
     cluster-01n01
                  HA      enabled  online
                                           e0b     iWARP  Up
                                           e1b     iWARP  Up
     cluster-02n02
                  DR      enabled offline
                                           e0b     iWARP  Up
                                           e1b     iWARP  Up
     cluster-02n01
                  AUX     enabled offline
                                           e0b     iWARP  Up
                                           e1b     iWARP  Up
12 entries were displayed.

  • 切换模拟失败、原因相同

cluster-01::*> metrocluster operation show
  (metrocluster operation show)
       Operation: switchover-simulate
           State: failed
      Start Time: 6/21/2023 09:13:05
        End Time: 6/21/2023 09:13:20
          Errors: Failed to validate the node and cluster components before the switchover operation.
                  cluster-02::cluster-02n01 (non-overridable veto): DR partner NVLog mirroring is not online. Make sure that the links between the two sites are healthy and properly configured.
                  cluster-02::cluster-02n02 (non-overridable veto): DR partner NVLog mirroring is not online. Make sure that the links between the two sites are healthy and properly configured.
                  cluster-01 (non-overridable veto): MetroCluster Vserver configuration state check failed. Run "metrocluster vserver show -cluster cluster-02" on both clusters to verify that "Configuration State" of all Vservers become healthy, then try the command again.

  • metrocluster vserver show 显示了Vserver运行状况不正常

cluster-01::*> metrocluster vserver show -cluster cluster-02

                              Cluster  : cluster-02
                              Vserver  : cluster-02
                      Partner Vserver  : cluster-01
                  Configuration State  : unhealthy
                        Stream Status  : idle

  • cluster peer show 正常

cluster-01::*> cluster peer show
Peer Cluster Name         Cluster Serial Number Availability   Authentication
------------------------- --------------------- -------------- --------------
cluster-02                1-80-000011           Available      ok

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.