问题描述

在 MetroCluster 系统中,一个或多个节点报告 AUSO 已禁用
 
ClusterA::> metrocluster show

Configuration: fabric

Cluster                        Entry Name             State
------------------------------ ---------------------- ---------------------
Local: ClusterA
                                 Configuration State  configured
                                                Mode  normal
                                AUSO Failure Domain auso-disabled
Remote: ClusterB
                                 Configuration State  configured
                                                Mode  normal
                                AUSO Failure Domain auso-disabled

 

ClusterB::*> system health alert show

Node: NodeB-01
Alert ID: NchmTwoNodeMccAUSODisabled_Alert
Resource: NodeB-01
Severity: Major
Indication Time: Fri Oct 03 01:38:27 2025
Suppress: false
Acknowledge: false
Probable Cause: NodeB-01 has automatic switchover disabled.
Possible Effect: On a controller fault it's disaster-recovery (DR)partner will not trigger an automatic switchover to
ensure Non-disruptive Operation.
Corrective Actions: Use "metrocluster modify -node-name NodeB-01-automatic-switchover-onfailure true" to enable automatic switchover.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.