由于SnapMirror\SnapVault策略错误、MetroCluster SVM可能不同步
适用场景
- MetroCluster
- SnapMirror
- SnapVault
问题描述
- 由于SnapMirror\SnapVault策略错误、MetroCluster SVM可能无法同步。
- 违规策略将在MetroCluster vserver show命令输出中命名。
Cluster1::*> metrocluster vserver show
Cluster : NetApp_Cluster
Vserver : VSERVER1
Partner Vserver : VSERVER1-mc
Configuration State : degraded
Stream Status : operation-failed
Corrective Action : Resynchronize the configuration using "metrocluster vserver resync" command. Contact technical support for assistance if configuration-state does not change to healthy.
Failed Row : Table Name: snapmirror_policy_ui, Operation: get, Fields: VSERVER1-mc vault_7day vault vserver-admin - 8 normal false always false - sv_vault 14 false 0 - - - - - - - false - - - - - - - - - - - b7e70ff0-4b2e-11ea-9f9d-00a0989db67c - unlimited -
Failed Reason : Apply failed for Object: snapmirror_policy_ui Method: baseline. Reason: Volume name not found for volume Data Set ID 1073743309 and volume Master Set ID 3236753984. (entry doesn't exist)