适用场景

  • ONTAP 9
  • MetroCluster IP
  • AFF A250

问题描述

  • 事件日志中报告的高延迟导致磁盘故障率增加
Tue Feb 1 08:00:00 +0100 [netapp01-01: disk_latency_monitor: shm.ssd.threshold.ioLatency:notice]: SSD 0m.i2.3L13 has exceeded the expected block latency in the current timeframe with an average latency of 10089 us and an average utilization of 37 percent. The next highest SSD latency: 1339 us. Disk 0m.i2.3L13 Shelf 0 Bay 18 [NETAPP  X] S/N [] UID []
  • ifstat -a 报告后端MCC端口上的CRC错误增加 
-- interface  e0d  (50 days, 0 hours, 0 minutes, 1 seconds) --
 CRC errors:    16984  | Runt frames:     0  | Fragment:     1344 
  • 命令会对事件日志中报告的远程驱动器执行操作

Thu Feb 11 08:00:00 +0100 [netapp01-01:scsi_cmdblk_strthr_admin: scsi.cmd.abortedByHost:error]: Disk device 0v.i2.2L4: Command aborted by host adapter: HA status 0x13: cdb 0x28:16712464:0001.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.