跳转到主内容

由于交换机端口上的链路较差或无链路、一条路径中缺少ATTO网桥

Views:
4
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>2009415180</a>
Last Updated:

适用场景

  • ONTAP 9
  • FAS/AFF系统
  • 光纤连接MetroCluster

问题描述

  • 通过事件日志中调用的适配器、所有节点中缺少一个ATTO网桥的路径:

[Node-102: isp2400_timeout_0: fci.device.quiesce:debug]: Adapter 1d encountered a command timeout on Unknown device Switch1:10.126 (0x00080a00) LUN 0 cdb 0x12 retry: 0 Quiescing the device.
[Node-102: isp2400_asyncd_0: fci.device.login.status:debug]: A login delay has occurred between Fibre Channel adapter 1d and unknown device Switch1:10.126 (0x00080a00), with error subcode 0x703.
[Node-101: isp2400_timeout_0: fci.device.login.failure:error]: A login failure has occurred between Fibre Channel adapter 1d and unknown device Switch1:10.126 (0x00080a00), with error subcode 0x703.
[Node-101: svc_queue_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED

  • 所有节点都从"四路径HA"配置过渡到"多路径HA"配置:

[Node-101: dsa_disc: shelf.config.tompha:info]: System has transitioned to multi-path HA attached storage

  • 受影响ATTO网桥的FC端口报告了多个错误:

get FCPortErrors all

; Fibre Channel Error Counts 
; Port | Link Failures | Sync Loss | Signal Loss | Invalid Tx | Invalid CRC
;==========================================================================
  1          1       3        0       0        0
  2        1957   922594816        0      216     14382

  • 连接到缺失ATTO网桥的交换机端口也会出现错误:

porterrshow     :
      frames    enc   crc   crc   too   too   bad   enc  disc link  loss   loss   frjt   fbsy  c3timeout  pcs   uncor
    tx    rx    in   err   g_eof  shrt   long   eof    out  c3   fail   sync   sig          tx  rx    err   err
  9:   3.0g   4.2g   0    0    0    0    0    0    0    1    0    0    0    0    0    0    1    0    0
 10:   1.9g   4.1g   0    2   1    0    1    0    0   892    4   0    4    0    0   892    0    0    0

  • 交换机端口上SFP的传输功率(Tx)低于 预期范围

Switch> sfpshow -all

=============
Port 10:
=============

Current:    7.508   mAmps
Voltage:    3304.2  mVolts
RX Power:   -1.5   dBm (706.9uW)
TX Power:   -5.2   dBm (302.0 uW)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.