跳转到主内容

由于 FC 端口摆动, ATTO 网桥重新启动

Views:
14
Visibility:
Public
Votes:
2
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • 光纤连接 MetroCluster
  • ONTAP 9
  • ATto FB7500 N
  • ATto固件3.35 及更低版本

问题描述

由于FC端口不活动、ATto网桥意外重新启动。
 
ATto网桥上可能出现错误。
示例:
08:18:22 07/30/21 INFO FC Async Event, Link Down, PTP/Fabric, 16Gb on FC Port 1 
08:18:22 07/30/21 INFO FC Port 1 Link Down detected.
08:18:22 07/30/21 INFO FC Loop Is Not Operational on FC Port 1 
08:18:22 07/30/21 INFO FC Port ID 0x000000 [0x000] LogOut  Pt:00000000000000000 
08:18:22 07/30/21 INFO FC Port ID 0x000000 [0x000] LogOut  Pt:00000000000000000 
08:18:22 07/30/21 INFO Initiator 0000000000000000 logged out.
08:18:22 07/30/21 INFO Initiator 0000000000000000 logged out.
08:18:22 07/30/21 CRIT FC Chip Error, Status: 0x00000000, Error1: 0x00000000,
08:18:22 07/30/21 CRIT  Error2: 0x00000000 on FC Port 1 
08:18:22 07/30/21 CRIT Software Interrupt Exception Detected (SWI) (001H)
 
get fcporterrors all ; Fibre Channel Error Counts ; Port | Link Failures | Sync Loss | Signal Loss | Invalid Tx | Invalid CRC ;========================================================================== 1 6110 44460 0 403860 144 2 1 4 0 28 0
 
集群上的EMS日志中可能会显示更多错误。
示例:
Fri Aug 13 13:54:59 +0200 [ClusterA-N1: dsbridge_admin: fc.bridge.fc.port.alert:alert]: Fibre Channel FibreBridge7500N Bridge ATTO_0000000000000000 S/N: FB7500N000000 WWN: 0000000000000000 FC Port FC_PORT1 offline. 
Fri Aug 13 14:03:06 +0200 [ClusterA-N1: dsbridge_admin: fc.bridge.fc.port.notice:notice]: Fibre Channel FibreBridge7500N Bridge ATTO_0000000000000000 S/N: FB7500N000000 WWN: 0000000000000000 FC Port FC_PORT1 connected. 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.