问题描述

  • 更换E系列控制器后、某些主机的iSCSI连接松动
  • Recovery Guru and MAJOR-EVENT-LOG (MEL)报告以下错误:
    • Loss of host-side connection redundancy detected
    • Volume not on preferred path due to AVT/RDAC failover
    • ALB_HOST_REDUNDANCY_LOST
    • NON_PREFERRED_PATH
  • 重新分布卷可临时解决这些错误、但几分钟后会再次检测到这些错误
  • 除了更换控制器之外、不会在控制器和主机上执行任何配置更改
  • STATE-CAPTURE-DATA > spmShow 表示更换后的控制器没有从配对控制器的某些主机建立iSCSI连接

更换控制器A后的示例:

Executing spmShow(0,0,0,0,0,0,0,0,0,0) on controller A:

---I-T-Nexus (PORT) Objects (ITN)---
ITNID InitiatorPort          TargetPort            Online
----- ------------------------------ ------------------------------ ------
x0005 Host_0000000000000003      iSCSI_TargetPortPR_Ah_ch7    on   <IQN>:<HOST1>
x0006 Host_0000000000000004      iSCSI_TargetPortPR_Ah_ch8    on   <IQN>:<HOST1>


Executing spmShow(0,0,0,0,0,0,0,0,0,0) on controller B:

---I-T-Nexus (PORT) Objects (ITN)---
ITNID InitiatorPort          TargetPort            Online
----- ------------------------------ ------------------------------ ------
x0005 Host_0000000100000004      iSCSI_TargetPortPR_Bh_ch8    off   <IQN>:<HOST1>
x0006 Host_0000000100000002      iSCSI_TargetPortPR_Bh_ch8    on   <IQN>:<HOST1>
x0007 Host_0000000100000002      iSCSI_TargetPortPR_Bh_ch8    on   <IQN>:<HOST1>
x0008 Host_0000000100000020      iSCSI_TargetPortPR_Bh_ch8    off   <IQN>:<HOST2>
x0009 Host_0000000100000001      iSCSI_TargetPortPR_Bh_ch7    on   <IQN>:<HOST2>
x000a Host_000000010000001f      iSCSI_TargetPortPR_Bh_ch7    off   <IQN>:<HOST1>
x000b Host_0000000100000002      iSCSI_TargetPortPR_Bh_ch8    off   <IQN>:<HOST2>
x000c Host_0000000100000001      iSCSI_TargetPortPR_Bh_ch7    on   <IQN>:<HOST2>
x000d Host_0000000100000002      iSCSI_TargetPortPR_Bh_ch8    on   <IQN>:<HOST3>
x000e Host_0000000100000002      iSCSI_TargetPortPR_Bh_ch8    on   <IQN>:<HOST3>

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.