适用场景
- NetApp E 系列
- 直接连接的Linux主机
问题描述
在Linux主机上更换HBA后、此链接不会出现并显示 Linkdown:
/sys/class/fc_host/host2/port_state
::::::::::::::
Online
::::::::::::::
/sys/class/fc_host/host3/port_state
::::::::::::::
Linkdown
SANtricity 恢复Guru报告:
NON_PREFERRED_PATH-Recovery Failure Type Code: 10
ALB_HOST_REDUNDANCY_LOST-Recovery Failure Type Code: 475
事件日志报告:
9102 Loss of host-side connection redundancy detected - Host <HostName><--CRITICAL
4011 Volume not on preferred path due to AVT/RDAC failover - Shelf __, Bay _ <--CRITICAL