在升级和控制器解除限制期间、控制器上会发出E系列待定配置警报
适用场景
- E 系列
- 在E5500上将控制器固件(CFW)从08.20.19.30升级到08.25.20.30
- 在E2800上将SANtricity操作系统从11.70.4R1升级到11.80.GA
问题描述
- 在执行CFW升级期间、某个控制器出现故障:
MEL Event - "6107 - This controller's alternate is non-functional and is being held in reset".
- 新CFW版本
Pending configuration
在 storage-array-profile > controllers"(存储阵列配置文件> 控制器)中的两个控制器上均列为
Controller in Tray 0, Slot A
Status: Online
Current configuration
Firmware version: 08.20.19.30
Appware version: 08.20.19.30
Bootware version: 08.20.19.30
NVSRAM version: N5501-820833-113
Pending configuration
Firmware version: 08.25.20.30
Appware version: 08.25.20.30
Bootware version: 08.25.20.30
NVSRAM version: N5501-825833-112
Transferred on: Wed Aug 19 20:19:16 EDT 2020
Controller in Tray 0, Slot B
Status: Online
Current configuration
Firmware version: 08.20.19.30
Appware version: 08.20.19.30
Bootware version: 08.20.19.30
NVSRAM version: N5501-820833-113
Pending configuration
Firmware version: 08.25.20.30
Appware version: 08.25.20.30
Bootware version: 08.25.20.30
NVSRAM version: N5501-825833-112
Transferred on: Wed Aug 19 20:19:16 EDT 2020