适用场景

  • NS224 架
  • NSM100磁盘架模块

问题描述

  • EMS日志报告磁盘架故障、可能会发出运行状况警报:

[cluster-01: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0x. Check fans, power supplies, disks, and temperature sensors.
[cluster-01: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 12345678901234567890 raised by monitor node-connect

  • 磁盘架模块在 storage show fault -v 命令输出(或 STORAGE-FAULT AutoSupport 部分:

Enclosure Status: normal
Channel: 0x
Shelf: 1
Shelf Type: NS224NSM100
Module Type: NSM100

Enclosure:
Element Status      Status Bytes  Status Descriptions
  1: OK         01,00,02,00  FAIL

Boot Device:
Element Status            Status Bytes  Status Descriptions
  1 [NSM100 A]   : OK         01,00,00,00   
  2 [NSM100 B]   : NONCRITICAL    03,00,00,00  

 