适用场景

  • ONTAP 9
  • callhome.nve.all已 用尽:警报

事件摘要

  • 当Flash Cache设备已达到使用寿命时、会显示此消息

验证

主叫事件

FLNVME:HA Group Notification from Node Name (Flash Cache NVMe Exhausted) ALERT

EMS日志
  • 运行 event log show -severity * -message-name callhome*

Sat Mar 12 13:12:12 +0100 [Node Name: gemini-notif-thread: callhome.nvme.exhausted:alert]: Callhome for Flash Cache NVMe Exhausted.

命令行
  • 运行 system node run -node <node name> -command sysconfig 
slot 1: Flash Cache NVMe Serial Number: XXXXXXXX Part Number: 119-00329 Hardware Revision: A0 Firmware Version: NA03 Firmware File: X3311_S00005000NVM Model Name: X3311A Capacity: 1024 GB State: failed 

解决方法

  • 请联系NetApp技术支持并参考此文章以获得进一步帮助。解决方案 可能需要更换部件。