NSM100 模块中的 Coin 电池出现电池故障错误 NS224 磁盘架
适用场景
NS224 架
问题描述
- NS224 磁盘架模块 NSM100 错误或警报:
Wed Feb 03 18:50:32 +0100 [node_name: dsa_worker4: ses.status.battery.error:error]: NS224NSM100 (S/N SHFHU0123456789) shelf 0 on channel 0x battery failure error for Coin Battery 1: not installed or hardware failure. This element is on the rear of the shelf, in bottom module (B).
Wed Feb 03 18:50:42 +0100 [node_name: dsa_worker3: ses.status.battery.threshErr:alert]: NS224NSM100 (S/N SHFHU0123456789) shelf 0 on channel 0x battery failure error for Coin Battery 1: critical status. This element is on the rear of the shelf, in top module (A).
- 存储故障输出
::> system node run -node <node_name> -command storage show fault -v
...
Coin Cell Battery:
Element Status Status Bytes Status Descriptions
1 [NSM100 A] : CRITICAL 02,02,0A,46 LCR
2 [NSM100 B] : OK 01,00,0B,34
- Coin 电池环境错误:
Coin Battery installed element list: 1, 2; with error: 1
Coin Battery information by element:
[1] Voltage: 2.630
[2] Voltage: 2.868
- 此错误可能是间歇性的