使用BMC固件的A900/FAS9500<16.3.
适用场景
使用BMC固件<16.3的AF-A900/FAS9500
问题描述
NetApp AFF A900和FAS9500系统会报告
nvram.battery.chargeFET.of
"有关NVRAM电池的事件消息、有时会在发生另一个与电池相关的硬件事件之前报告此消息、例如:Fri Aug 05 23:48:32 +0200 [cluster_node_name: env_mgr: nvram.battery.voltage.high:EMERGENCY]: The NVRAM battery voltage is critically high (8700 mV). To prevent data loss, the system will shut down in 5 minutes.
Fri Aug 05 23:48:42 +0200 [cluster_node_name: env_mgr: nvram.battery.chargeFET.off:error]: The NVRAM battery charge FET is off. To prevent data loss, the system will shut down in 24 hours.
Fri Aug 05 23:49:13 +0200 [cluster_node_name: env_mgr: nvram.battery.voltage.normal:info]: The NVRAM battery voltage is normal.
Fri Aug 05 23:49:53 +0200 [cluster_node_name: env_mgr: nvram.battery.chargeFET.normal:info]: The NVRAM battery charge FET is on.