跳转到主内容

FabricSwitchFanFail或SwitchFanFail警报—AutoSupport 消息

Views:
2
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • 集群网络交换
  • MetroCluster 光纤交换机
  • NetApp集群交换机
  • Broadcom 交换机
  • Cisco 交换机
  • 致电主页查看运行状况监控器进程cshm: FabricSwitchFan或SwitchFanFail警报

事件摘要

如果未检测到风扇电源、并且风扇状态显示为FAILED、则会发送FabricFanSwitchFan或SwitchFanail_Alert

验证

AutoSupport 消息

HA Group Notification from Node Name (Health Monitor process cshm: SwitchFanFail_Alert[Switch Name/Fan-2]) ALERT

System Notification from Node Name (Health Monitor process schm: FabricSwitchFanFail_Alert[Switch WWN]) ALERT

EMS日志

event log show -severity * -message-name callhome*

[Node Name: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: FabricFanSwitch or SwitchFanFail_Alert[Switch Name/WWN].

命令行

system health alert show -node <node name> -monitor cluster-switch -alert-id FabricSwitchFanFail_Alert

system health alert show -node <node name> -monitor cluster-switch -alert-id SwitchFanFail_Alert


Node: Netapp-a
Resource: Fan Module-3
Severity: Major
Indication Time: <date/time>
Suppress: false
Acknowledge: false
Probable Cause: The fan "Fan Module-3" on switch "Switch_Name"
has failed.
Possible Effect: Failure of the fan in the switch "Switch_Name"
might affect its cooling.
Corrective Actions: 1) Ensure that the fans in the switch are operating correctly by using the command "storage switch show -cooling".
2) Ensure that the fan FRUs are properly inserted and
operational.

解决方法

  1. 验证是否已安装电源。
  2. 验证电源是否已通电。
  3. 如果确定电源存在故障、请予以更换。
  • 注意:如果这是计划内维护活动的一部分、请考虑在维护期间禁用自动创建案例:

 