问题描述
- EMS日志会报告 一个磁盘上的
scsi cmd checkCondition
错误、并自动恢复这些错误
[node: Error] scsi_cmdblk_strthr_admin scsi cmd checkCondition: deviceType="Disk" deviceName="0b.00.10"cdb="0x88:000000016f1e7200:00000200" sSenseKey="SCSI:aborted command" sSenseCode="" iSenseKey="0xb" iASC="0x4b" iASCQ="0x3" iFRU="0x0" DTime="1" disk_information=""
[node: Debug] pmcsas_admin_0 scsi cmd retrySuccess: deviceType="Disk" deviceName="0b.00.10" retryCount="1" freeRetryCount="0" cdb="0x88:000000016f1e7200:00000200" dTime="118"
[node: Error] scsi_cmdblk_strthr_admin scsi cmd checkCondition: deviceType="Disk" deviceName="0b.00.10" cdb="0x88:000000016f840e00:00000200" sSenseKey="SCSI:aborted command" sSenseCode="" iSenseKey="0xb" iASC="0x4b" iASCQ="0x3" iFRU="0x0" DTime="1" disk_information=""
[node: Debug] pmcsas_admin_0 scsi cmd retrySuccess: deviceType="Disk" deviceName="0b.00.10" retryCount="1" freeRetryCount="0" cdb="0x88:000000016f840e00:00000200" dTime="118"
[node: Error] scsi_cmdblk_strthr_admin scsi cmd checkCondition: deviceType="Disk" deviceName="0b.00.10"cdb="0x88:0000000170f82a00:00000200" sSenseKey="SCSI:aborted command" sSenseCode="" iSenseKey="0xb" iASC="0x4b" iASCQ="0x3" iFRU="0x0" DTime="2" disk_information=""
[node: Debug] pmcsas_admin_0 scsi cmd retrySuccess: deviceType="Disk" deviceName="0b.00.10" retryCount="1" freeRetryCount="0" cdb="0x88:0000000170f82a00:00000200" dTime="96"
[node: scsi_cmdblk_strthr_admin: scsi.cmd.notReadyCondition:notice]: Disk device 1a.04.22: Device returns not yet ready: CDB 0x28:ccc88d50:0200: Sense Data SCSI:not ready - Drive spinning up (0x2 - 0x4 0x1 0x0)(4061).
[node: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0a.01.7: Check Condition: CDB 0x2f:bb0a0800:0400: Sense Data SCSI:no sense - (0x0 - 0x0 0x0 0x0)(32). ......
[node: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device 0d.01.7: request successful after retry #0/#12: cdb 0x88:00000002f243ddc0:00000008 (20148).
- 系统日志事件详细信息
EMS标识符 | scsi.cmd.checkCondition |
系统日志消息 | %s设备%s:检查条件:CDB %s:检测数据%s -%s (0x%x - 0x%x 0x%x 0x%x)(%d)。%s |
严重性 | 错误 |
描述 | 从设备收到检查条件时会出现此消息。检查条件是指目标设备向请求主机报告信息条件或错误状态的机制。生成此事件的条件是在执行命令期间发生的错误、未通过重试请求清除、或者是报告当前操作或介质状态的信息条件。 |
- 驱动器报告缺失:
12:33:45 +0100 [node4: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr1_SAS_euhstorp13/plex0/rg0/bsasswpj5-2:9.126L91 Shelf 0 Bay 10 [NETAPP X343_HCBFE1T8A10 NA06] S/N [08H5L03A] UID [5000CCA0:2C4283C4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.