跳转到主内容

EMS日志在磁盘上报告"SCSI cmd checkConation"错误

Views:
230
Visibility:
Public
Votes:
1
Category:
fas-systems
Specialty:
HW
Last Updated:

适用场景

  • ONTAP 9
  • 驱动器

问题描述

  • EMS日志会报告 一个磁盘上的scsi cmd checkCondition 错误、并自动恢复这些错误

[node: Error] scsi_cmdblk_strthr_admin scsi cmd checkCondition: deviceType="Disk" deviceName="0b.00.10"cdb="0x88:000000016f1e7200:00000200" sSenseKey="SCSI:aborted command" sSenseCode="" iSenseKey="0xb" iASC="0x4b" iASCQ="0x3" iFRU="0x0" DTime="1" disk_information=""
[node: Debug] pmcsas_admin_0 scsi cmd retrySuccess: deviceType="Disk" deviceName="0b.00.10" retryCount="1" freeRetryCount="0" cdb="0x88:000000016f1e7200:00000200" dTime="118"
[node: Error] scsi_cmdblk_strthr_admin scsi cmd checkCondition: deviceType="Disk" deviceName="0b.00.10" cdb="0x88:000000016f840e00:00000200" sSenseKey="SCSI:aborted command" sSenseCode="" iSenseKey="0xb" iASC="0x4b" iASCQ="0x3" iFRU="0x0" DTime="1" disk_information=""
[node: Debug] pmcsas_admin_0 scsi cmd retrySuccess: deviceType="Disk" deviceName="0b.00.10" retryCount="1" freeRetryCount="0" cdb="0x88:000000016f840e00:00000200" dTime="118"
[node: Error] scsi_cmdblk_strthr_admin scsi cmd checkCondition: deviceType="Disk" deviceName="0b.00.10"cdb="0x88:0000000170f82a00:00000200" sSenseKey="SCSI:aborted command" sSenseCode="" iSenseKey="0xb" iASC="0x4b" iASCQ="0x3" iFRU="0x0" DTime="2" disk_information=""
[node: Debug] pmcsas_admin_0 scsi cmd retrySuccess: deviceType="Disk" deviceName="0b.00.10" retryCount="1" freeRetryCount="0" cdb="0x88:0000000170f82a00:00000200" dTime="96"

[node: scsi_cmdblk_strthr_admin: scsi.cmd.notReadyCondition:notice]: Disk device 1a.04.22: Device returns not yet ready: CDB 0x28:ccc88d50:0200: Sense Data SCSI:not ready - Drive spinning up (0x2 - 0x4 0x1 0x0)(4061).

[node: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0a.01.7: Check Condition: CDB 0x2f:bb0a0800:0400: Sense Data SCSI:no sense - (0x0 - 0x0 0x0 0x0)(32). ...... 
[node: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device 0d.01.7: request successful after retry #0/#12: cdb 0x88:00000002f243ddc0:00000008 (20148).

  • 系统日志事件详细信息
EMS标识符 scsi.cmd.checkCondition
系统日志消息 %s设备%s:检查条件:CDB %s:检测数据%s -%s (0x%x - 0x%x 0x%x 0x%x)(%d)。%s
严重性 错误
描述 从设备收到检查条件时会出现此消息。检查条件是指目标设备向请求主机报告信息条件或错误状态的机制。生成此事件的条件是在执行命令期间发生的错误、未通过重试请求清除、或者是报告当前操作或介质状态的信息条件。
  • 驱动器报告缺失:

12:33:45 +0100 [node4: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr1_SAS_euhstorp13/plex0/rg0/bsasswpj5-2:9.126L91 Shelf 0 Bay 10 [NETAPP   X343_HCBFE1T8A10 NA06] S/N [08H5L03A] UID [5000CCA0:2C4283C4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.